In this Document
Goal
Solution
References


Created from <SR 3-8781991759>

Applies to:

Exadata X3-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Goal

Event logs shows errors during ILOM config restore:

Unable to restore property '/SP/users/MSUser/password decryption failed.
Unable to restore property /SP/users/root/password decryption failed
Unable to restore property '/SP/services/ssh/keys/rsa/privatekey' decryption failed
Unable to restore property '/SP/services/ssh/keys/dsa/privatekey' decryption failed

 

Solution

The errors reported during ILOM config restore is due to a change in ILOM root password.

ILOM root password has been changed since taken the config backup.

You may wish to either change the password back to it's original value that was present during the backup or create a new backup archive.
 

References

<NOTE:1009715.1> - Integrated Lights Out Manager (ILOM) CLI Quick Reference