![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1644679.1 : Exadata HW [JP] ILOM Restore Failure In Storage Server
In this Document
Created from <SR 3-8781991759> Applies to:Exadata X3-2 Hardware - Version All Versions and laterInformation in this document applies to any platform. GoalEvent logs shows errors during ILOM config restore: SolutionThe errors reported during ILOM config restore is due to a change in ILOM root password. You may wish to either change the password back to it's original value that was present during the backup or create a new backup archive. References<NOTE:1009715.1> - Integrated Lights Out Manager (ILOM) CLI Quick Reference<NOTE:1448073.1> - Engineered Systems Upgrade/Supportability Reference Doc (INTERNAL ONLY) Attachments This solution has no attachment |
||||||||||||||||
|