Asset ID: |
1-71-1643391.1 |
Update Date: | 2016-04-07 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1643391.1
:
SL3000 - Base Module FAN Failure: How to Replace ECM BASE FAN Module Assembly
Related Items |
- Sun StorageTek SL3000 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Action Plan for Oracle Internal FE's
Created from <SR 3-8794323041>
Applies to:
Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Replace ECM BASE FAN Module Assembly in SL3000
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Trained on SL3000 library.
TASK COMPLEXITY: 1
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
SL3000 tape library fan failure will be displayed on the SL Console under Tools > Library > Status > Status Module
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
To remove and replace in a ECM BASE FAN module assembly in StorageTek SL3000 Modular Library System
Fan Tray Assembly
The fan tray assembly is located at the rear of the base module.
Refer to FIGURE 1-5 Chapter 1 Page 11 in StorageTek SL3000 Service Manual.
Fan Tray Assembly Removal
To remove the assembly:
1. Open the rear doors of the base module.
2. Loosen the green thumbscrews that hold the assmebly in place,
3. Pull out the assembly.
Fan Tray Assembly Replacement:
To replace the fan assembly:
1. Insert the new fan tray assembly and tighten the thumb screws.
2. Verify that the fans are working and that the fault LED is OFF.
REFER TO LINK(s) FOR PART & LOCATION INFORMATION:
SL3000 Service Manual: http://download-adc.oracle.com/archive/cd_ns/E22211_10/en/E20911/E20911_09.pdf
https://mosemp.us.oracle.com/handbook_internal/Systems/STK_Part_images/ECM_Fan_Assy_SL3000.jpg
419901006 [F] ECM Fan Tray Assembly
> https://mosemp.us.oracle.com/handbook_internal/Systems/STK_Part_images/ECM_Fan_Assy_SL3000.html
Attachments