Asset ID: |
1-71-1640736.1 |
Update Date: | 2018-05-16 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1640736.1
:
How to Replace a Sun Server X4-2 Coin Cell Battery
Related Items |
- Exalogic Elastic Cloud X4-2 Eighth Rack
- Oracle Database Appliance X4-2
- Exadata X4-2 Hardware
- Exalogic Elastic Cloud X4-2 Quarter Rack
- Exalogic Elastic Cloud X4-2 Full Rack
- Zero Data Loss Recovery Appliance X4 Hardware
- Exalogic Elastic Cloud X4-2 Hardware
- Exadata X4-2 Full Rack
- Exadata X4-2 Quarter Rack
- Sun Server X4-2
- Exalogic Elastic Cloud X4-2 Half Rack
- Exadata X4-2 Half Rack
- Oracle Advanced Support Gateway Server X4-2
- Exadata X4-2 Eighth Rack
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
Applies to:
Exadata X4-2 Eighth Rack - Version All Versions to All Versions [Release All Releases]
Sun Server X4-2 - Version All Versions to All Versions [Release All Releases]
Oracle Database Appliance X4-2 - Version All Versions to All Versions [Release All Releases]
Exalogic Elastic Cloud X4-2 Quarter Rack - Version X4 to X4 [Release X4]
Exalogic Elastic Cloud X4-2 Eighth Rack - Version X4 to X4 [Release X4]
x86_64
Goal
How to Replace a Sun Server X4-2 Coin Cell Battery.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Server X4-2 Coin Cell Battery needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications and OS. Then power off the server and remove the AC power cords from the system.
A data backup is not a prerequisite but is a wise precaution.
Note: If this server is part of an Exadata, please follow shutdown instructions in Section 1 of DOC ID:
1539451.1
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Prepare the server for service.
- Power off the server and disconnect the power cords from the power supplies.
- Extend the server to the maintenance position in the rack.
- Attach an anti-static wrist strap.
- Remove the top cover.
2. Locate and Remove the Battery.
- The system battery is a 3V Lithium Coin Cell Battery (CR2032 or BR2032) which is located on the system board directly behind Processor 0.
- To remove the battery from the retainer, place your finger under the side of the battery nearest the rear of the server and gently lift the battery up and out of the retainer.
3. Install the Replacement Battery.
- Unpackage the replacement battery.
- Press the new battery into the battery retainer with the positive side (+) facing up.
4. Return the Server to operation
- Replace the top cover
- Remove any anti-static measures that were used.
- Return the server to it's normal operating position within the rack.
- Re-install the AC power cords and any data cables that were removed.
- Power on server.
5. Adjust system clocks if needed
- If the ILOM is not configured to use ntp adjust the time by logging into the ILOM cli and setting the clock using the following command format
-> set /SP/clock datetime=MMDDhhmmYYYY
- When powering on the host for the first time adjust the system date/time by pressing F2 to go into the BIOS setup. The date and time can be adjusted in the "Main" menu section. After setting the time correctly navigate to the "Save&Exit" section and select the "Save Changes and Reset" option.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID:
1539451.1
REFERENCE INFORMATION:
Sun Server X4-2 Documentation
http://docs.oracle.com/cd/E36975_01/index.html
Oracle Integrated Lights Out Manager (ILOM) 3.1 Documentation
http://docs.oracle.com/cd/E24707_01/html/E24528/index.html
How to shutdown the Exadata database nodes and storage cells in a rolling fashion so certain hardware tasks can be performed. (Doc ID 1539451.1)
Attachments
This solution has no attachment