![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1640474.1 : How to Remove and Replace a Netra T1 AC200/DC200 Server Hard Disk:ATR:1640474.1:1
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential). Applies to:Sun Netra T1 AC200 Server - Version Not Applicable to Not Applicable [Release N/A]Sun Netra T1 Hardware - Version Not Applicable to Not Applicable [Release N/A] Sun Netra T1 DC200 Server - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. GoalHow to Remove and Replace a Netra T1 AC200/DC200 Hard Disk ********************************************************************* SolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Netra T1 AC200/DC200 product training is desirable but not required TIME ESTIMATE: 40 mins TASK COMPLEXITY: 1 FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: PROBLEM OVERVIEW: Disk failure WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: The operating system should be configured by the customer such that the disk drive is free for replacement. The hard disk drives are hot-pluggable modules. You do not need to power down the system or remove it from the rack to install or remove hard disk drives. WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?: Installing and Removing Hard Disk Drive The hard disk drives are hot-pluggable modules. You do not need to power off the server or remove it from the rack to install or remove hard disk drives. 1. Remove the front bezel. Release the bezel from the server by pressing in on the tabs at either end of the bezel. Note – When inserting a hard disk drive into its enclosure, make sure the top of the disk drive is touching the top of the enclosure. If you try to install it with the bottom of the disk drive touching the bottom of the enclosure, the drive will not align with the slide rails inside the enclosure, and you will not be able to insert the drive. * If you are removing a hard disk drive, locate the latch at the front of the disk drive and slide it to the right. This causes the metal lever to open. 4. Replace the grilles and front bezel
OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO Boot system and verify functionality. Reconfigure disk as previously configured. e.g. Part of raid set or mounted file-system or raw partition or other. Restart software applications per applicable administration guides to resume system operation. PARTS NOTE: https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_T1_AC200/components.html https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_T1_DC200/components.html
REFERENCE INFORMATION: Netra T1 AC200/DC200 Server User's Guide: http://docs.oracle.com/cd/E19102-01/nt1.ac200.srvr/ Attachments This solution has no attachment |
||||||||||||||
|