Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: Netra T1 AC200/DC200 are FRU parts so internal

Applies to:

Sun Netra T1 Hardware - Version Not Applicable to Not Applicable [Release N/A]
Sun Netra T1 AC200 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Netra T1 DC200 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

 How to Remove and Replace a Netra T1 AC200/DC200 CPU Fan

*********************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1527058.1
*********************************************************************

Solution

DISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:

Netra T1 AC200/DC200 product training is desirable but not required

TIME ESTIMATE: 40 mins

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: CPU Fan failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

If a data backup is not required it is still a wise precaution.

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Replacing the CPU Fan (Fan 3)

Caution – The procedure below is for the attention of qualified service engineers only. Before touching or replacing any components inside the Netra T1 server,
disconnect all cables and open the server. Always place the server on a grounded ESD pad and wear a properly grounded antistatic wrist strap.

1. Open the Netra T1 server. Make sure you disconnect all external cables and pay particular attention to the information about how to prevent electro-static discharge from your body from damaging the components of the server.

2. With the server open and seated on top of an ESD pad, and with a properly grounded anti-static wrist strap on your wrist, disconnect the power cable for Fan
3 from the system board. Fan 3 is located in the center of the system board on top of the CPU mounting

3. Press down on the long arm of the fan’s metal fastening clip and then, with a finger of your other hand, unhook the clip from the CPU mounting.
The long arm is the one that extends towards the rear of the server.

4. Lift the fan and clip about 60 o until it becomes possible to release the second clip which is at the front of the CPU mounting.

5. With the fan unclipped from the CPU mounting, lift it away and discard it.

6. Put the new fan onto the CPU mounting.

7. Push down on the short arm of the new fan’s clip until the clip hooks over the plastic lip at the front of the CPU mounting.

8. Push down on the long arm of the clip until the clip hooks over the plastic lip at the back of the CPU mounting.

9. Connect the fan power cable to its connector on the system board.

10. Replace the system cover and tighten the captive screw

OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO
RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot the system and verify all components are working properly.

PARTS NOTE:

https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_T1_AC200/components.html

https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_T1_DC200/components.html

 

REFERENCE INFORMATION:

Netra T1 AC200/DC200 Server User's Guide: http://docs.oracle.com/cd/E19102-01/nt1.ac200.srvr/


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback