![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1640460.1 : How to Remove and Replace a Netra T1 AC200/DC200 Server CPU Fan:ATR:1640460.1:1
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential). Applies to:Sun Netra T1 Hardware - Version Not Applicable to Not Applicable [Release N/A]Sun Netra T1 AC200 Server - Version Not Applicable to Not Applicable [Release N/A] Sun Netra T1 DC200 Server - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. GoalHow to Remove and Replace a Netra T1 AC200/DC200 CPU Fan ********************************************************************* SolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Netra T1 AC200/DC200 product training is desirable but not required TIME ESTIMATE: 40 mins TASK COMPLEXITY: 1 FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: PROBLEM OVERVIEW: CPU Fan failure WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: If a data backup is not required it is still a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?: Replacing the CPU Fan (Fan 3) Caution – The procedure below is for the attention of qualified service engineers only. Before touching or replacing any components inside the Netra T1 server, 1. Open the Netra T1 server. Make sure you disconnect all external cables and pay particular attention to the information about how to prevent electro-static discharge from your body from damaging the components of the server. 2. With the server open and seated on top of an ESD pad, and with a properly grounded anti-static wrist strap on your wrist, disconnect the power cable for Fan 3. Press down on the long arm of the fan’s metal fastening clip and then, with a finger of your other hand, unhook the clip from the CPU mounting. 4. Lift the fan and clip about 60 o until it becomes possible to release the second clip which is at the front of the CPU mounting. 5. With the fan unclipped from the CPU mounting, lift it away and discard it. 6. Put the new fan onto the CPU mounting. 7. Push down on the short arm of the new fan’s clip until the clip hooks over the plastic lip at the front of the CPU mounting. 8. Push down on the long arm of the clip until the clip hooks over the plastic lip at the back of the CPU mounting. 9. Connect the fan power cable to its connector on the system board. 10. Replace the system cover and tighten the captive screw OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO Boot the system and verify all components are working properly. PARTS NOTE: https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_T1_AC200/components.html https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_T1_DC200/components.html
REFERENCE INFORMATION: Netra T1 AC200/DC200 Server User's Guide: http://docs.oracle.com/cd/E19102-01/nt1.ac200.srvr/ Attachments This solution has no attachment |
||||||||||||||
|