Solution Type Technical Instruction Sure Solution 1640436.1 : How to Remove and Replace a Netra T1 AC200/DC200 Server NVRAM:ATR:1640436.1:1
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential). Applies to:Sun Netra T1 Hardware - Version Not Applicable to Not Applicable [Release N/A]Sun Netra T1 AC200 Server - Version Not Applicable to Not Applicable [Release N/A] Sun Netra T1 DC200 Server - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. GoalHow to Remove and Replace a Netra T1 AC200/DC200 NVRAM ********************************************************************* SolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Netra T1 AC200/DC200 product training is desirable but not required TIME ESTIMATE: 40 mins TASK COMPLEXITY: 1 FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: PROBLEM OVERVIEW: NVRAM failure WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: If a data backup is not required it is still a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?: Replacing the NVRAM Caution – The procedure below is for the attention of qualified service engineers only. Before touching or replacing any components inside the Netra T1 server, The NVRAM chip on the Netra T1 server’s system board contains a lithium battery that in time may need replacing. If you see the following message on your console Warning -- Real-Time-Clock (and NVRAM) battery is low Caution – There is a danger of explosion if the NVRAM chip is incorrectly replaced. Replace it only with a component of the same type as the used one. To replace the chip, follow any instructions supplied with the new component. Dispose of the used component according to the manufacturer’s instructions. 1. Make a note of the current settings of the environment parameters diag-switch? and diag-level. You will need these values to carry out Step 5. ok printenv diag-switch?
ok printenv diag-switch?
2. Open the Netra T1 server. Make sure all external cables are disconnected and pay particular attention to the information about how to prevent electrostatic discharge from your body from damaging the components of the server. 3. Carefully take the NVRAM chip carrier lengthwise between your thumb and forefinger and pull it out of its socket. 4. Holding the new NVRAM chip carrier in a similar fashion between your thumb and forefinger, position it over the socket and press firmly until the connectors 5. When you have reconnected the cables and powered the server on, type the following at the ok OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO Boot the system and verify all components are working properly by verifying POST has completed. Logon to root account after booted and running the command # prtdiag ensuring all components present. PARTS NOTE: https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_T1_AC200/components.html https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_T1_DC200/components.html
REFERENCE INFORMATION: Netra T1 AC200/DC200 Server User's Guide: http://docs.oracle.com/cd/E19102-01/nt1.ac200.srvr/ Attachments This solution has no attachment |
||||||||||||||
|