Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1639893.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1639893.1 :   How to Remove and Replace a Netra T1 Model 100/105 DVD:ATR:1639893.1:1  


Related Items
  • Sun Netra T1100 Server
  •  
  • Sun Netra T1105 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: Netra T1 Model 100/105 are FRU parts so internal

Applies to:

Sun Netra T1105 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Netra T1100 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

 How to Remove and Replace a Netra T1 Model 100/105 CD/DVD

*********************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1527058.1
*********************************************************************

Solution

DISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:

Netra T1 Model 100/105 product training is desirable but not required

TIME ESTIMATE: 30 mins

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: CD/DVD failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Note – If you are going to install a PCI card, install the CD-ROM drive first. If you have a PCI card already installed, you will need to remove it before installing the
CD-ROM drive

Installing CD/DVD drive


1. Remove the top cover
2. Remove the front bezel by pressing the latch at each end
3. Remove any PCI card installed in the system
4. Squeeze and pull out the blanking panel.
5. Slide the connector card into the slot behind the CD-ROM drive bay
6. Connect the cable to the slot under the PCI card
7. Slide the CD-ROM drive into its bay until the catch clicks
8. Re-install the PCI card (if necessary)
9. Replace the system cover and screws.
10. Replace the front bezel

OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO
RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:

https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_t1_100/components.html

https://mosemp.us.oracle.com/handbook_internal/Systems/Netra_t1_105/components.html

 

REFERENCE INFORMATION:

Netra T1 Model 100/105 Service Manual: http://docs.oracle.com/cd/E19628-01/806-4707-10/806-4707-10.pdf