Solution Type  Technical Instruction Sure

Solution  1633669.1 :   SL8500- Fan Status in Library  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-8651348241>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

SL8500 builds cooling feature for drives and electronics module. Fans are located in each drive trays and Card Cage Assembly.

Goal

 How to know Fan status for EM (Electronics Module) Card Cage.

Solution

Confirmed FSC_8.31 code has capability to use "hbc fan status" CLI command.  FRS_6.07 does not work with "syntax error at fan"

SL8500> HBC fan status

  requestId

  requestId 2966301

  Attributes Fan Combined Ok true
             Fan Ok1         true

             Fan Ok2         true

             Fault Led       off

             Present         true

             Threshold       36

  Object     Card            fan1

  Done          

  Failure Count 0

  Success Count 1

COMPLETED

 

 