Asset ID: |
1-71-1632207.1 |
Update Date: | 2017-11-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1632207.1
:
How to replace a Network Express Module (NEM) on a Sun Blade 6000 Modular Chassis:ATR:1632207.1:0
Related Items |
- Sun Blade 6048 System
- Sun Blade 6000 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Blade 6000 System - Version All Versions and later
Sun Blade 6048 System - Version All Versions and later
Information in this document applies to any platform.
Goal
Replace a Network Express Module (NEM) on a Sun Blade 6000 Modular Chassis
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TASK COMPLEXITY: 0
TIME ESTIMATE: 45 minutes
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: NEM failure
OBTAIN CUSTOMER ACCEPTANCE
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
You can remove and replace a NEM from a powered-on system using a hot-swap operation, as well as from a powered-off system
WHAT ACTIONS ARE REQUIRED:
Remove a NEM
1. Remove all cables from the NEM
2. Press together and hold the ejector buttons on both the right and left ejector levers.
3. To unlatch the NEM from the chassis, open the ejector levers by extending them outward.
4. Holding the opened ejector levers, pull the NEM toward you until you can pull the rest of the module out by hand.
Caution – If you are not immediately replacing the NEM, install a NEM filler panel to ensure proper system temperature and operation
Install a NEM
1. Align the NEM with the vacant NEM slot. If you are installing only one NEM, it should be installed in the bottom (NEM 0) slot.
2. Ensure that:
■ The RJ-45 port connectors of the NEM are facing you.
■ The NEM ejector levers are fully opened.
■ The NEM ejector levers are on the top of the module.
3. Slide the NEM into the vacant NEM chassis slot until you feel it stop.
4. Close the ejector levers to secure the NEM in the chassis.
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
N/A
PARTS NOTE: Include NEM location:
https://support.oracle.com/handbook_private/Systems/SunBlade6000/components.html
REFERENCE INFORMATION:
Sun Blade 6000 Server Service Manual http://docs.oracle.com/cd/E19938-01/E20918/E20918.pdf
Attachments
This solution has no attachment