Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1627066.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1627066.1 :   How to replace Sun Enterprise 250 Fan Tray Assembly:ATR:1627066.1:1  


Related Items
  • Sun Enterprise 250 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU part

Applies to:

Sun Enterprise 250 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

 

  Sun Enterprise 250, How to replace Fan Tray Assembly

Solution

 

DISPATCH INSTRUCTIONS


WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Sun Enterprise 250 product training and field experience

TASK COMPLEXITY: 1

TIME ESTIMATE: 40 minutes

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW: Fan Tray Assembly failure

OBTAIN CUSTOMER ACCEPTANCE

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

 WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE:


Removing Fan Tray Assembly

1. Power off the system.

2. Remove the Side Access Panel

3. Disconnect the fan tray cable from the fan tray assembly.Press the tab to release the connector.

2. Deflect the tab that secures the fan tray in the upper guide.

3. Slide the fan tray out of the system.Hold the tray at the center so it pulls out evenly.

Installing the Fan Tray Assembly

1. Align the fan tray assembly with the upper and lower fan tray guides.Hold the fan tray so that the arrow on its outer edge is facing up.

2. Slide the fan tray into the top and bottom guides.Hold the tray at the center so that the tray slides into the guides evenly.

3. Continue to push the fan tray assembly until the deflecting tab locks and the assembly is held securely in the guides.

4. Connect the fan tray cable to the fan tray assembly.Connect the end of the cable that is labeled P2. The connector is keyed and attaches
in only one way. Press the connector until the tab locks the cable in place.

5. To reassemble the system, install the Side Access Panel

6. Verify correct operation of the power supply by checking the fan and LED indicators on the rear of the supply. The fan should start spinning and both LEDs should light within three seconds of completing a hot-plug installation

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.



PARTS NOTE: Include Sun Enterprise 250 Fan Tray Assembly:

https://mosemp.us.oracle.com/handbook_internal/Systems/E250/components.html

 

ADDITIONAL COMMENTS:

Please refer to the Sun Enterprise 250 Server Owner's Guide: http://docs.oracle.com/cd/E19088-01/250.srvr/805-5160-10/805-5160-10.pdf