Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1626969.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1626969.1 :   How to replace Sun Enterprise 250 Memory DIMM:ATR:1626969.1:1  


Related Items
  • Sun Enterprise 250 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU part

Applies to:

Sun Enterprise 250 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

 

  Sun Enterprise 250, How to replace Memory DIMM

Solution

 

DISPATCH INSTRUCTIONS


WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
Sun Enterprise 250 product training and field experience

TASK COMPLEXITY: 1

TIME ESTIMATE: 40 minutes

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW: DIMM failure

OBTAIN CUSTOMER ACCEPTANCE

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

 WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE:

CautionDual inline memory modules (DIMMs) are made of electronic components that are extremely sensitive to static electricity. Static from your clothes or work environment can destroy the modules.Do not remove any DIMM from its antistatic packaging until you are ready to install it on the main logic board. Handle the modules only by their edges. Do not touch the components or any metal parts. Always wear a grounding strap when you handle the modules.


Replacing the memory DIMM

1. Locate the DIMM module you want to remove on the main logic board.

2. Push the ejection lever away from the memory module and eject it from the socket.

3. Grasp the top corners of the memory module and pull it out of its socket.Place the module on an antistatic mat.


Installing the New Memory DIMM

1. Remove the new memory module from its antistatic packaging.

2. Locate the socket into which you will install the module.

Note – Each bank used must contain four modules of equal capacity (for example,four 32-Mbyte memory modules, four 64-Mbyte modules) to function properly. Do not mix capacities within the same bank.

3. Orient the module so that the small notch on the bottom corner of the module is at the same end as the socket’s ejection lever.

4. Align the module with its socket until it contacts the socket evenly along the socket’s length.

5. Push firmly down on both ends of the module until the bottom edge is firmly seated in the socket. Ensure that all module contacts engage in the socket.

6. Install the Side Access Panel

7. When you are ready to restart the system, be sure to run POST and OpenBoot Diagnostic tests to verify that the system functions correctly with the new parts you have just installed. You must also perform a reconfiguration boot so that your system is able to recognize the new device(s)

 

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.



PARTS NOTE: Include Sun Enterprise 250 Memory DIMM:

https://mosemp.us.oracle.com/handbook_internal/Systems/E250/components.html#Memory

 

ADDITIONAL COMMENTS:

Please refer to the Sun Enterprise 250 Server Owner's Guide: http://docs.oracle.com/cd/E19088-01/250.srvr/805-5160-10/805-5160-10.pdf