Goal
Having issues removing internal drive that is under veritas and sun cluster control
Solution
Action Plan :
A) What : Take down time and Stop all applications and perform a reconfiguration reboot
$ boot -- -r
Why : This will eliminate any false entries.
If still issue persists, Then go to
B)
1. For now just rename /dev/cfg ( we will delete later when we confirm the issue is resolved)
$ mv /dev/cfg /dev/cfg.orig
2. Stop all applications and do a reconfiguration reboot
$ boot -- -r
When the system comes up, it will not find /dev/cfg and will create a new one.
3. Check that the newly created controller numbers/disks are consistent.
4.Once confirmed, delete the saved directory:
$ rm -rf /dev/cfg.orig
Attachments