![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1624672.1 : Sun Storage 7000 Unified Storage System: How to Clear the SNMP Logs
In this Document
Created from <SR 3-8527203528> Applies to:Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]Sun Storage 7110 Unified Storage System - Version All Versions to All Versions [Release All Releases] Sun Storage 7410 Unified Storage System - Version All Versions to All Versions [Release All Releases] Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases] Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases] 7000 Appliance OS (Fishworks) GoalThe SNMP logs still show old alerts that have been cleared from the NAS. Like old disk errors or network card errors, and we need to clear these down.
SolutionIn the CLI, select the SNMP service: Configuration > Services > SNMP
1) Type disable to take the service offline
2) Now move the file CLI:> confirm shell cp /var/log/snmpd.log /var/log/snmpd.log.old
3) Now zero the file CLI:> confirm shell cat /dev/null > /var/log/snmpd.log
3) Restart the SNMP service Configuration > Services > SNMP > enable
Clients using the SNMP service should now not see any old messages.
References<NOTE:1587750.1> - Sun Storage 7000 Unified Storage System: Disk remains marked as 'faulty' in hardware view, despite several replacements done. (Unable to clear FMA event)Attachments This solution has no attachment |
||||||||||||||||
|