Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1624672.1
Update Date:2016-02-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  1624672.1 :   Sun Storage 7000 Unified Storage System: How to Clear the SNMP Logs  


Related Items
  • Sun ZFS Storage 7320
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7420
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Goal
Solution
References


Created from <SR 3-8527203528>

Applies to:

Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]
Sun Storage 7110 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7410 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Goal

The SNMP logs still show old alerts that have been cleared from the NAS.

Like old disk errors or network card errors, and we need to clear these down.

 

Solution

In the CLI, select the SNMP service:

Configuration > Services > SNMP

 

1)  Type  disable  to take the service offline

 

2)  Now move the file

CLI:> confirm shell  cp /var/log/snmpd.log  /var/log/snmpd.log.old


3)  Now zero the file

CLI:> confirm shell cat /dev/null > /var/log/snmpd.log


3)  Restart the SNMP service

Configuration > Services > SNMP > enable

 

Clients using the SNMP service should now not see any old messages.

 

References

<NOTE:1587750.1> - Sun Storage 7000 Unified Storage System: Disk remains marked as 'faulty' in hardware view, despite several replacements done. (Unable to clear FMA event)