![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1621226.1 : Pillar Axiom: Host HBA Ports Status Are shown as "Not Connected"
Created from <SR 3-8510067788> Applies to:Pillar Axiom 600 Storage System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalThe goal of this document is to explain HP-UX behavior when connected to an Axiom Storage System. SolutionAfter LUN mapping is configured on an Axiom Storage System for a HP-UX host, the Axiom GUI shows the host HBA status as "Not Connected" Based on WWNs they are originating from HP: 50060b000021d7d2 -> HP (Array / Tape) To clarify status: 1- Double check the LUN mapping on axiom side. 2- Check and confirm whether the host can perform IO to a mapped LUN. 3- On HP-UX platforms, some HBA device drivers use a different approach—they log out from the connection when there is no traffic to send. A HP-UX HBA port often shows as Not Connected even though there is an enabled physical connection between the ports. 4- If there is a problem performing IO to this LUN, please check the LUN number used during host mapping. If there are SAN hosts accessing the LUNs using HP-UX initiator ports and HP HBAs, one can enable the HP-UX option. When this option is enabled, the system determines the LUN numbering to use using the HP-UX addressing scheme, allowing up to 255 LUNs. NOTE: with the HP-UX option enabled, the host cannot use a visible LUN with ID 0
- Click on the Storage icon in the top context pane. Attachments This solution has no attachment |
||||||||||||
|