![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1618257.1 : SL8500 - How to Load a Diagnostic Tape into a Drive Using SLConsole
In this Document
Applies to:Sun StorageTek T10000 Tape Drive - Version All Versions and laterSun StorageTek SL8500 Modular Library System - Version All Versions and later LTO Tape Drive - Version All Versions and later Information in this document applies to any platform. I need to run diagnostics on a T10000 tape drive. There are 3 diag tapes 1 1 -13 1 13 DG000T1 1 2 -13 1 12 DG003T1 1 3 -13 1 12 DG006T1 Is there a way to load 1 of those tapes in drive slot 48 or 1,2,2,1,1 with SLConsole? GoalSL8500 - How to Load a Diagnostic Tape into a drive using SLConsole. SolutionThere are two ways this can be done: 1. Use the "DiagMove" feature under the "Diagnostics" tab in SL Console. or 2. Use the "RcvrMove" feature under the "Diagnostics" tab in SL Console. With this option, use "RcvrMove" to move a tape out to the CAP from a slot and then do a "RcvrMove" from the CAP (Cartridge Access Port) to a drive. To dismount the drive, do a "RcvrMove" from the drive to the CAP and then from the CAP back to the slot. Attachments This solution has no attachment |
||||||||||||||
|