Solution Type  Technical Instruction Sure

Solution  1618257.1 :   SL8500 - How to Load a Diagnostic Tape into a Drive Using SLConsole  


Related Items
  • LTO Tape Drive
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Goal
Solution


Applies to:

Sun StorageTek T10000 Tape Drive - Version All Versions and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
LTO Tape Drive - Version All Versions and later
Information in this document applies to any platform.

I need to run diagnostics on a T10000 tape drive.
There are 3 diag tapes
1 1 -13 1 13 DG000T1
1 2 -13 1 12 DG003T1
1 3 -13 1 12 DG006T1
Is there a way to load 1 of those tapes in drive slot 48 or 1,2,2,1,1 with SLConsole?

Goal

 SL8500 - How to Load a Diagnostic Tape into a drive using SLConsole.

Solution

There are two ways this can be done:

1. Use the "DiagMove" feature under the "Diagnostics" tab in SL Console.

or

2. Use the "RcvrMove" feature under the "Diagnostics" tab in SL Console.  With this option, use "RcvrMove" to move a tape out to the CAP from a slot and then do a "RcvrMove" from the CAP (Cartridge Access Port) to a drive.  To dismount the drive, do a "RcvrMove" from the drive to the CAP and then from the CAP back to the slot.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.