Goal

SL500 Capacity Calculations - LTO Only

Solution

 Description                                                     Physical Capacity             License Value

===================================================================================

Base Module Only(Shipped Standard)                         30                        Limited Base
BM as last module                                                    50                        FullBase
BM with any module below                                         66                        FullBase

====================================================================================

Adding DEM as the last module                                  77                        ThirdDEM(in increments of 26,26,25)
Adding DEM with any module below                             84                        ThirdDEM(in increments of 28,28,28)

===================================================================================

Adding a CEM after a DEM or BM                                 104                      FullCEM
Adding a CEM with any module below                          114                      FullCEM

===================================================================================

CEM after CEM                                                          110                     FullCEM
CEM with any module below                                        120                     FullCEM

 

Note: This information is taken from SL500 Systems Assurance Guide.  Detailed Capacity calculations alongs with examples are described in the System Assurance Guide.

Refer to Capacity on Demand section in the SL500 Systems Assurance Guide.

http://docs.oracle.com/cd/E24292_01/en/E21060/E21060_07.pdf