![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1610402.1 : How to test SNMP trap forwarding with IB switch or KVM on Exadata
In this Document
Created from <SR 3-7717446251> Applies to:Enterprise Manager for Exadata - Version 12.1.0.1.0 to 12.1.0.5.0 [Release 12.1]Exadata Database Machine X2-8 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalWhen to do this? Sometimes you would have configured the SNMP Trap Forwarding on Exadata compute nodes and would like to test the SNMP traps would be delivered to the EM agent running on the Exadata compute nodes. In such case, you could try these steps to test the SNMP trap forwarding. SolutionThe SNMP trap forwarding test can be done through KVM, however if the KVM is not present then this can be done alternatively with IB switch.
This is documented in http://docs.oracle.com/cd/E24628_01/doc.121/e27442/ch4_post_discovery.htm#BABFGAIF
- Connect to the IB Switch ILOM cli ssh ilom-admin@{switch name or IP address}
- Execute below commands. -> cd /SP/alertmgmt/rules/3 -> set destination=<COMPUTE_NODE_IP> -> set level=minor -> set /SP/alertmgmt/rules/3 testrule=true - Check that snmptrapd logs messages in the /var/log/messages file from the IP address of the IB Switch.
Referenceshttp://docs.oracle.com/cd/E24628_01/doc.121/e27442/ch4_post_discovery.htm#BABFGAIFAttachments This solution has no attachment |
||||||||||||||||
|