Solution Type Technical Instruction Sure Solution 1607903.1 : How to replace Sun Fire V120 CPU Fan:ATR:1607903.1:1
In this Document
Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential). Applies to:Sun Fire V120 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. Goal
Sun Fire V120, How to replace CPU Fan (Fan 3) Solution
DISPATCH INSTRUCTIONS OBTAIN CUSTOMER ACCEPTANCE WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE: Replacing CPU fan (Fan 3) Caution – The procedure below is for the attention of qualified service engineers only. Before touching or replacing any components inside the server, disconnect all 1. Open the server. 2. With the server open and seated on top of a grounded ESD pad, and with a properly grounded antistatic wrist strap on your wrist, disconnect Fan 3’s power 3. Take the fan between your forefinger and thumb and lift it out of its cradle. 4. Take the new fan and position it into the fan’s cradle. 5. Connect the new fan’s power cable to its connector on the system board. 6. Replace the server’s cover and tighten the captive screw WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://mosemp.us.oracle.com/handbook_internal/Systems/SunFireV120/components.html
ADDITIONAL COMMENTS: Attachments This solution has no attachment |
||||||||||||||
|