![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1606041.1 : How to replace Sun Fire V120 Power Supply:ATR:1606041.1:0
In this Document
Applies to:Sun Fire V120 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. Goal
Sun Fire V120, How to replace Power Supply Solution
DISPATCH INSTRUCTIONS OBTAIN CUSTOMER ACCEPTANCE WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTIONS ARE REQUIRED: Replacing the Power Supply Unit Caution – The procedure below is for the attention of qualified service engineers only. Before touching or replacing any components inside the server, disconnect all 1. Open the server. Make sure you disconnect all external cables and pay particular attention to the information about how to prevent electro-static discharge from your body from damaging the components of the server. 2. With the server open and seated on top of an ESD pad, and with a properly grounded antistatic wrist strap on your wrist, disconnect the power supply cables 3. Undo the two rear fixing screws. 4. Move the power supply unit (PSU) towards the front of the system to release it from the location tabs in the base. Lift it away from the chassis. 5. Lift the new PSU over the location tabs and slide it backwards into place. 6. Secure the two rear fixing screws. 7. Connect the power supply cables to the connectors on the system board. 8. Replace the server’s cover and tighten the captive screw.
WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://support.oracle.com/handbook_private/Systems/SunFireV120/components.html
ADDITIONAL COMMENTS: Attachments This solution has no attachment |
||||||||||||||
|