![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1606040.1 : How to replace Sun Fire V120 memory DIMM:ATR:1606040.1:0
In this Document
Applies to:Sun Fire V120 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. Goal
Sun Fire V120, How to replace memory DIMM Solution
DISPATCH INSTRUCTIONS OBTAIN CUSTOMER ACCEPTANCE WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTIONS ARE REQUIRED: Installing and Removing Memory There are four memory module sockets on the server’s system board. You can install a 256 or 512 MB DIMM into each socket. For the maximum 2 Gbytes of memory, 1. Remove the top cover Make sure you wear an antistatic wrist strap and that you disconnect all power cables. 2. Insert the memory module into a vacant DIMM socket, or, if you are removing memory, open the latches at the sides of the socket and remove the module. 3. Replace the server’s cover and tighten the captive screw Note – There are four DIMM slots. The one nearest to the CPU fan is slot 0. The one nearest to the power supply unit is slot 3. Put the first DIMM in slot 0, and install
WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://support.oracle.com/handbook_private/Systems/SunFireV120/components.html
ADDITIONAL COMMENTS: Attachments This solution has no attachment |
||||||||||||||
|