![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1605993.1 : Pillar Axiom: How To Change The NTP Server Settings
Created from <SR 3-8150990521> Applies to:Pillar Axiom 500 Storage System - Version All Versions to All Versions [Release All Releases]Pillar Axiom 600 Storage System - Version All Versions to All Versions [Release All Releases] Pillar Axiom 300 Storage System - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalHow to change the NTP server settings SolutionA Microsoft Windows system should not be used as an NTP server for Unix/Linux clients as it will not work. The Axiom is a Linux NTP client.
The following Documents explain the reasons why: NTP Sync Problem with Windows NTP Server and Linux NTP Client (Doc ID 2201343.1) NTP sync problem with Microsoft Windows NTP server (clock dispersion) (Doc ID 1018671.1)
For an Axiom that is running software release 4.x and below: Log into the GUI using an account with administrator privileges.
For an Axiom that is running software release 5.x: Log into the GUI using an account with administrator privileges. Click on the "Configure" tab. Then click on "System Time" under Global Settings on the left hand side. Right click in the right-hand window pane and select "Modify System Time". You can set/change the NTP settings on the "Modify System Time" window that opens.
Attachments This solution has no attachment |
||||||||||||
|