Goal
Solution


Applies to:

Sun Fire V120 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

 

  Sun Fire V120, How to replace System Configuration Card Reader

Solution

 

DISPATCH INSTRUCTIONS


WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TASK COMPLEXITY: 0

TIME ESTIMATE: 45 minutes

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: System Configuration Card Reader

OBTAIN CUSTOMER ACCEPTANCE

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

 WHAT ACTIONS ARE REQUIRED:

Replacing the Memory Card Reader for the System Configuration Card

1. Open the server by following the instructions in Chapter 4 (See Sun Fire V120 and Netra 120 Server User's Guide)
Make sure all external cables are disconnected and pay particular attention to the information about how to prevent electrostatic discharge from your body from
damaging the components of the server.

2. With the server open and seated on top of an ESD pad, and with a properly grounded antistatic wrist strap on your wrist, remove the power cable from the
connector on the memory card reader board.

3. Unscrew the screws fixing the memory card reader board into the top of the CD-ROM drive bay. Do not discard the screws.

4. Remove the old system configuration card reader.

5. Position the new memory card reader board by lining up its fixing holes with the holes in the top of the CD-ROM drive enclosure.

6. Insert and tighten the fixing screws.

7. Attach the power cable to the memory card reader board.

 

 

WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.



PARTS NOTE: Include Sun Fire V120 System Card Reader:

https://support.oracle.com/handbook_private/Systems/SunFireV120/components.html

 

ADDITIONAL COMMENTS:

Please refer to the Sun Fire V120 and Netra 120 Server User's Guide: http://docs.oracle.com/cd/E19088-01/v120.srvr/816-2090-10/816-2090-10.pdf