![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1605403.1 : How to replace Sun Fire V120 System Configuration Card:ATR:1605403.1:0
In this Document
Applies to:Sun Fire V120 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. Goal
Sun Fire V120, How to replace System Configuration Card Reader Solution
DISPATCH INSTRUCTIONS OBTAIN CUSTOMER ACCEPTANCE WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTIONS ARE REQUIRED: Replacing the Memory Card Reader for the System Configuration Card 1. Open the server by following the instructions in Chapter 4 (See Sun Fire V120 and Netra 120 Server User's Guide) 2. With the server open and seated on top of an ESD pad, and with a properly grounded antistatic wrist strap on your wrist, remove the power cable from the 3. Unscrew the screws fixing the memory card reader board into the top of the CD-ROM drive bay. Do not discard the screws. 4. Remove the old system configuration card reader. 5. Position the new memory card reader board by lining up its fixing holes with the holes in the top of the CD-ROM drive enclosure. 6. Insert and tighten the fixing screws. 7. Attach the power cable to the memory card reader board.
WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://support.oracle.com/handbook_private/Systems/SunFireV120/components.html
ADDITIONAL COMMENTS: Attachments This solution has no attachment |
||||||||||||||
|