Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1603081.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1603081.1 :   How to replace Sun Fire V125 Power Supply:ATR:1603081.1:1  


Related Items
  • Sun Fire V125 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential INTERNAL - Do not distribute to customer (OracleConfidential).
Reason: FRU part

Applies to:

Sun Fire V125 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

 

  Sun Fire V125, How to replace Power Supply

Solution

 

DISPATCH INSTRUCTIONS


WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
V125 Product training and field experience

TASK COMPLEXITY: 1

TIME ESTIMATE: 50 minutes

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW: PSU failure

OBTAIN CUSTOMER ACCEPTANCE

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

 WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE:

Removing the PSU
1. Power off the server.

2. Ensure that the server is properly grounded.

3. Remove the cover assembly.

4. Disconnect the cables leading to the system board and interface board.
To access the cable connector to the interface board, open the front cover assembly.
5. Undo the two screws on the back panel of the server.
6. Move the PSU towards the front of the server to release it from the locating tab on
the base of the server.
7. Lift the PSU out of the chassis.

 

Installing a PSU
1. Position the new PSU over the location tab and slide it towards the back of the
server.
2. Install and tighten the two screws on the back panel of the server.
3. Connect the power supply wiring harness to the connectors on the system board
and interface board.
4. Install the cover assembly.

 

 

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.



PARTS NOTE: Include Sun Fire V125 Power Supply:

https://mosemp.us.oracle.com/handbook_internal/Systems/SunFireV125/components.html

 

ADDITIONAL COMMENTS:

Please refer to the Sun Fire V125 Server Service Manual: http://docs.oracle.com/cd/E19088-01/v125.srvr/819-7421-10/819-7421-10.pdf


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.