Sun Fire V125, How to replace Lower Interface Board Solution
DISPATCH INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. WHAT ACTION DOES THE FIELD ENGINEER/CUSTOMER ADMINISTRATOR NEED TO TAKE: The interface board assemblies handle the connections between the system board and the components in the front section of the server. The assemblies are positioned Removing a Lower Interface Board Assembly 1. Power off the server. 4. Remove DVD drive, if one is fitted in the system. 5. Remove the cover assembly. 7. Disconnect the PSU cable. 8. Disconnect the system configuration card reader cable. 9. Unscrew the eight screws that secure the LIB to the server’s chassis as shown in 10. Lift the LIB assembly part of the way out of the server chassis. 11. Disconnect the cable from the bezel assembly. 12. Remove the LIB from the server. Installing a Lower Interface Board Assembly 1. Locate the new LIB assembly using the screw holes at each corner as guides. 2. Screw the LIB into place. 3. Attach the bezel PCB, PSU, and system board cables. 4. Install the cover assembly.
OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://mosemp.us.oracle.com/handbook_internal/Systems/SunFireV125/components.html
ADDITIONAL COMMENTS: Attachments This solution has no attachment |
||||||||||||||
|