![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1601475.1 : How to replace Sun Fire V125 Hard Drive:ATR:1601475.1:0
In this Document
Applies to:Sun Fire V125 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. Goal
Sun Fire V125, How to replace Hard Drives Solution
DISPATCH INSTRUCTIONS REMOVAL/REPLACEMENT INSTRUCTIONS OBTAIN CUSTOMER ACCEPTANCE WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : The operating system should be configured by the customer such that the disk drive is free for replacement. WHAT ACTIONS ARE REQUIRED: For information on removing a hard drive while the operating server is running Removing a Hard Drive 1. Ensure that you are properly grounded. 3. Check that the blue indicator indicator is lit on the hard drive. The blue indicator comes on when the hard drive is ready to remove. 4. Slide the catch at the front of the hard drive to the right. The handle on the front of the hard drive releases. 5. Pull the handle and remove the hard drive from the server by sliding the drive out from its bay. Installing a Hard Drive 1. Slide the catch on the front of the hard drive to the right. This releases the hard drive. The lever must be open before you insert the hard drive 2. Slide the hard drive into its bay at the front of the server. Push the drive in firmly until the metal lever starts to close. The hard drive has 3. Push the metal lever until the hard drive clicks into place. 4. Close the bezel. WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
https://support.oracle.com/handbook_private/Systems/SunFireV125/SunFireV125.html
SPECIAL Instructions: When replacing, a 73 GB Drive (540-6600) may be replaced with a 146 GB Drive (540-6602). Refer to doc 1911174.1 for details
ADDITIONAL COMMENTS: Attachments This solution has no attachment |
||||||||||||||||
|