Goal

 

  Sun Fire V125, How to replace PCI card

Solution

 

DISPATCH INSTRUCTIONS


WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TASK COMPLEXITY: 0

TIME ESTIMATE: 40 minutes
 

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW: PCI card failure

OBTAIN CUSTOMER ACCEPTANCE

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

 WHAT ACTIONS ARE REQUIRED:

Adding a PCI card

1. Power off the server.

2. Ensure that the server is properly grounded.

3. Open the back section of the server.

4. Unscrew the PCI lockdown screw on the back of the server.

5. Remove the PCI lockdown bracket on the inside of the server.

6. Slide the PCI card support clear of the PCI card.

7. Disconnect and remove the PCI card.

Replacing PCI card

1. Locate the PCI card in the appropriate slot and press it firmly into the connector.

2. Locate the PCI card support so that it supports the back of the card.

3. Attach the PCI lockdown bracket and tighten the PCI lockdown screw.

 

 WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:

Restart software applications per applicable administration guides to resume system operation.



PARTS NOTE: Include Sun Fire V125 PCI card:

https://support.oracle.com/handbook_private/Systems/SunFireV125/SunFireV125.html

 

ADDITIONAL COMMENTS:

Please refer to the Sun Fire V125 Server Service Manual: http://docs.oracle.com/cd/E19088-01/v125.srvr/819-7421-10/819-7421-10.pdf


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback