How to replace Sun Fire V125 System Configuration Card Reader:ATR:1600991.1:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Fire V125 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
Sun Fire V125, How to replace System Configuration Card Reader
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TASK COMPLEXITY: 0
TIME ESTIMATE: 30 minutes
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: System Configuration Card reader failure
OBTAIN CUSTOMER ACCEPTANCE
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
WHAT ACTIONS ARE REQUIRED:
Removing the System Configuration Card Reader
1. Power off the server.
2. Ensure that the server is properly grounded.
3. Remove the front section of the cover assembly.
4. Remove the system configuration card.
5. Disconnect the cable leading to the lower interface board from the configuration
card reader
6. Unclip the system configuration card reader.
Hold the reader board firmly and unclip one corner at a time by pulling up. Take care
not to damage the On/Standby switch when you remove the assembly.
Installing the System Configuration Card Reader
1. Position the new configuration card reader board by lining up the fixing holes
with the clips in the top of the DVD drive enclosure.
2. Press the new reader board firmly onto the clips to secure it in place.
3. Reconnect the system configuration card reader power cable.
4. Install the system configuration card.
WHAT ACTIONS ARE REQUIRED TO RETURN the SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE: Include Sun Fire V125 System Configuration Card Reader:
https://support.oracle.com/handbook_private/Systems/SunFireV125/SunFireV125.html
ADDITIONAL COMMENTS:
Please refer to the Sun Fire V125 Server Service Manual: http://docs.oracle.com/cd/E19088-01/v125.srvr/819-7421-10/819-7421-10.pdf