Solution Type Technical Instruction Sure Solution 1600257.1 : How to Replace an Acme Packet 3810/3820/4500 Chassis [VCAP]
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Net-Net 3810 - Version S-Cx6.0.x and laterAcme Packet 3820 - Version S-Cx6.0.x and later Acme Packet 4500 - Version S-Cx6.0.x and later Acme Packet 4500 Acme Packet OS Acme Packet 3820 GoalHow to replace a Acme Packet 3820 chassis, 3810 chassis or 4500 chassis. SolutionDISPATCH INSTRUCTIONSThis task relates to service of an ACME PACKET product. Parts specified in this task should be delivered using a cost effective next day delivery method, and may require to be back ordered from a Tier 1 location. The Planned End Date should be set to a time on the second business day to enable this, unless specific instructions from the TSC engineer indicate otherwise. Refer to https://stbeehive.oracle.com/content/dav/st/GDMI/Public/REFBF134.htm or specific instructions. WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:Acme Packet NN38x0/NN4500 Training. Note: #2 Philips is required
TIME ESTIMATE: 90 minutesTASK COMPLEXITY: 4FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:TEMPORARY INSTRUCTIONS due to bug 24450808 for problems with the MOD-0039-60 HDDDue to a recent issue where Acme Packet systems equipped with a MOD-0039-60 HDD may fail to boot and have no Console output, when replacing a chassis it is important to be sure that the problem is not the HDD, or that there are no problems with the HDD. The FS Task should have sent both a replacement chassis and a replacement HDD as a precaution. Before replacing the chassis, first the system should be checked by removing the HDD and attempting to boot the unit. This should have been done prior to the FS Task being opened, but it would be wise to check if this is not documented in the SR as having been done. Simply remove the HDD and with a known working serial console cable connected, power up the system. if the unit shows console output, the problem may be simply an HDD failure. Refer to KM Document 2172091.1 Diagnosing problems with an Acme Packet 4500 (3800/4600/6300) which has a hard drive when it fails to boot up. If the problem continues to appear, this is an indication that the problem is still likely to be the chassis and you should proceed with the replacement as indicated below. If, when finished the system is still showing problems booting and has no console output, it may be necessary to replace the HDD as well. If this is not necessary, the HDD should be returned as unneeded. PROBLEM OVERVIEW:Acme Packet3820, 3810 or 4500 Chassis Replacement WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :A data backup is not a prerequisite, but is a wise precaution. If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications, OS and logically removing the Acme Packet 3820 system from the network. Then power off the server and remove the AC power cords and all other cabling from the system. Note: The replacement chassis does not contain a storage device (HDD) or security module (SSM). These items need to be removed from the failed unit and installed into the replacement chassis. WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:1. Prepare the server for service.
2. Opening chassis
3. Locating the SSM2 card and HDD device
4. Installing top lid
5: Install Network Interface Unit (NIU) card and power supplies that were set aside earlier 6. Install chassis into rack
OBTAIN CUSTOMER ACCEPTANCEWHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?:A: Legacy customer will need to request a new license key to enable the software to function correctly. License keys are tied to the chassis serial number.
http://www.oracle.com/us/support/licensecodes/index.html
- Old and new chassis serial number (Note: using the command 'show prom-info mainboard', be sure to use the "Serial Number" for your license request rather than the “Oracle System Serial Number”. The Serial number will contain ONLY numbers, no alpha characters. Refer to Doc ID 1600257.1 for more information) - License Key for existing system - SR (Service Request) number that was assigned for this issue - Software name/revision
B: Customer should now restore the boot image and configuration setting on the replacement system REFERENCE INFORMATION:Net-Net 3820 Hardware Installation Guide http://docs.oracle.com/cd/E50394_01/doc/acmepacket3820_installation.pdf
Acme Packet 4500 Hardware Installation Guide http://docs.oracle.com/cd/E50395_01/doc/acmepacket4500_installation.pdf Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||
|