Asset ID: |
1-71-1597863.1 |
Update Date: | 2017-02-03 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1597863.1
:
How to Replace a Memory DIMM on a Sun Netra X3-2 and a ZFS Storage ZS3-2 (Netra X4270M3) [Video]
Related Items |
- Oracle ZFS Storage ZS3-2
- Netra Server X3-2
- Netra Server X3-2 for Acme Packet
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
- _KM>Content>Video
|
Applies to:
Netra Server X3-2 - Version All Versions to All Versions [Release All Releases]
Netra Server X3-2 for Acme Packet - Version P-Cz1.0.0 to S-Cz7.1.2 [Release P-Cz1.0 to S-Cz7.0]
Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases]
x86_64
Goal
How to Replace a Memory DIMM on a Sun Netra X3-2, ZS3-2 (Netra X4270M3)
Solution
Video - How to Replace an Oracle ZFS Storage ZS3-2 Memory DIMM (7:28) 
CAP PROBLEM OVERVIEW: Replace a Memory DIMM
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:
Sun Netra Server X3-2 Server Training.
Note: When you add or remove DIMMs to the motherboard, there are guidelines to follow:
■ You can configure an odd number of DIMMs, however an equally-balanced even number of DIMMs provides better performance.
■ When you add DIMMs in pairs, the pair should be of the same part number.
■ Fill all of the blue slots first, and then add DIMMs to the white slots
■ If you will mix DIMM capacities, install the largest capacities first, then consecutively smaller capacities.
■ If a slot is empty, install a DIMM filler.
TIME ESTIMATE: 45 minutes
TASK COMPLEXITY: 3-FRU
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications and OS. Then power off the server and remove the AC power cords from the system.
A data backup is not a prerequisite but is a wise precaution.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Prepare the server for service.
- Power off the server and disconnect the power cords from the power supplies.
- Extend the server to the maintenance position in the rack.
- Attach an anti-static wrist strap.
- Remove the top cover.
- Remove the front air filter
- Remove all of the fan modules.
- Remove the fan tray.
- Raise the Drive Tray to the Service Position.
- Remove the air duct.
2. Locate the DIMM to remove.
3. Press down and out on the release levers at both ends of the DIMM slot.
4. Lift the DIMM up and out the slot.
5. Set the DIMM aside.
6. Repeat from Step 2 for any additional DIMMs to be removed.
7. Confirm the release levers of the slot where you are installing the DIMM are OPEN.
8. Align the DIMM to the location where it installs into the slot.
Ensure that the notch in the DIMM lines up with the key in the slot.
9. Insert the DIMM into the slot, pressing firmly so that both release levers click closed.
10. Repeat from Step 7 through Step 9 for any additional DIMMs that you are installing.
- Install the air duct.
- Secure the Drive Tray.
- Install the fan tray.
- Install all of the fan modules.
- Install the front air filter.
- Replace the top cover
- Remove any anti-static measures that were used.
- Return the server to it's normal operating position within the rack.
- Re-install the AC power cords and any data cables that were removed.
- Power on server. Verify that the Power/OK indicator led lights steady on.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
REFERENCE INFORMATION:
Sun Netra Server X3-2 Documentation
http://docs.oracle.com/cd/E27124_01/index.html
Attachments
This solution has no attachment