Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1597858.1
Update Date:2015-10-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  1597858.1 :   How to Replace a Netra Server X3-2 PSU (Power Supply Unit)  


Related Items
  • Oracle ZFS Storage ZS3-2
  •  
  • Netra Server X3-2
  •  
  • Netra Server X3-2 for Acme Packet
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




Applies to:

Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases]
Netra Server X3-2 - Version All Versions to All Versions [Release All Releases]
Netra Server X3-2 for Acme Packet - Version P-Cz1.0.0 to S-Cz7.1.2 [Release P-Cz1.0 to S-Cz7.0]
x86_64

Goal

How to Replace a PSU on a Sun Netra X3-2 (Netra X4270M3), Oracle ZFS ZS3-2

Solution

CAP PROBLEM OVERVIEW: Replace a PSU

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:
Sun Netra Server X3-2 Server Training.

Note: Removing a power supply is a hot-swap operation. You do not need to power off the server before you remove the power supply.

TIME ESTIMATE: 15 minutes

TASK COMPLEXITY: 3-FRU

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

You do not need to power off the server before you remove the power supply

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Determine which power supply to remove.

2. Disconnect the power cord from the power supply.

3. Press the release tab to the left and pull on the handle.

4. Continue to pull on the handle to slide the power supply out of the chassis.

5. Set the power supply aside.

Installing Power Supply Unit

1. Align the power supply to the location where it installs into the chassis.

2. Confirm the release levers of the slot where you are installing the DIMM are OPEN.

3. Slide the power supply into the chassis until the power supply seats and the release tab clicks.

4. Attach the power cord.

 

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot up system and verify full functionality

REFERENCE INFORMATION:
Sun Netra Server X3-2 Documentation

http://docs.oracle.com/cd/E27124_01/index.html