![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1597486.1 : How to Remove and Replace a Netra X4450 Power Supply Unit
In this Document
Applies to:Sun Netra X4450 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. GoalHow to Remove and Replace a Netra X4450 Power Supply Unit. SolutionDISPATCH INSTRUCTIONS - COMPLEXITY: 0
The server’s redundant hot-swappable power supplies enable you to remove and replace one or two power supplies without shutting the server down, provided that the other power supplies are online and working.
Step I: Remove a Power Supply 1. Identify which power supply requires replacement. A lighted amber indicator on a power supply indicates that a failure was detected. 2. Disconnect the power cord from the faulty power supply. 3. Grasp the power supply handle, and push the power supply latch to the right. 4. Pull the power supply out of the chassis.
Step II: Install a Power Supply 1. Remove the replacement power supply from its packaging, and place the power supply on an antistatic mat. 2. Slide the power supply into bay until it is fully seated. 3. Reconnect the power cord to the power supply. 4. Verify that the amber indicator on the replaced power supply and that the Service Required Indicators are not lit.
OBTAIN CUSTOMER ACCEPTANCE
REFERENCE INFORMATION:
Attachments This solution has no attachment |
||||||||||||||
|