![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1597484.1 : Acme Packet: How to Format /boot dir
In this Document
Applies to:Net-Net 4250 - Version C5.x.x and laterAcme Packet OS GoalHow to format /boot dir. SolutionIn the rare instance of an Session Director (SD) failing to correctly boot, for example failing to extrace a software image, it may be necessary to format the boot partition. boot device : wancom0
processor number : 0 host name : topgun file name : sd414p5.gz inet on ethernet (e) : 172.30.20.100:ffff0000 inet on backplane (b): host inet (h) : 172.30.0.125 gateway inet (g) : 172.30.0.1 user (u) : vxftp ftp password (pw) (blank = use rsh): vxftp flags (f) : 0x8 0x40000008 <-----------CHANGE BOOT FLAG to 0x40000008 target name (tn) : TAC-SD-100 startup script (s) : other (o) :
boot device : wancom
unit number : 0 processor number : 0 host name : topgun file name : sd414p5.gz inet on ethernet (e) : 172.30.20.100:ffff0000 host inet (h) : 172.30.0.125 gateway inet (g) : 172.30.0.1 user (u) : vxftp ftp password (pw) : vxftp flags (f) : 0x40000008 target name (tn) : TAC-SD-100
boot flags: 0x40000008
TFFS mounting /boot ... /boot mounted TFFS mounting /code ... /code mounted Source based routing is disabled. /ramdrv is default dir
boot device : wancom0
processor number : 0 host name : topgun file name : sd414p5.gz inet on ethernet (e) : 172.30.20.100:ffff0000 inet on backplane (b): host inet (h) : 172.30.0.125 gateway inet (g) : 172.30.0.1 user (u) : vxftp ftp password (pw) (blank = use rsh): vxftp flags (f) : 0x40000008 0x8 <-----------CHANGE BOOT FLAG BACK TO 0x8 target name (tn) : TAC-SD-100 startup script (s) : other (o) :
boot device : wancom
unit number : 0 processor number : 0 host name : topgun file name : sd414p5.gz inet on ethernet (e) : 172.30.20.100:ffff0000 host inet (h) : 172.30.0.125 gateway inet (g) : 172.30.0.1 user (u) : vxftp ftp password (pw) : vxftp flags (f) : 0x8 target name (tn) : TAC-SD-100
Attachments This solution has no attachment |
||||||||||||||
|