Asset ID: |
1-71-1595991.1 |
Update Date: | 2017-09-26 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1595991.1
:
How to Replace a Netra T4-2 Rear Fan:ATR:1595991.1:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
Applies to:
Netra SPARC T4-2 Server - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Replace a Netra T4-2 Rear Fan
**********************************************************************************
To report errors or request improvements on this procedure, please Add a comment on Doc ID: 1595991.1
**********************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED?: No special skills required, Customer Replaceable Unit (CRU) procedure
Time Estimate: 30 minutes
Task Complexity: 0
REMOVAL/REPLACEMENT INSTRUCTIONS
PROBLEM OVERVIEW: rear fan module failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
The rear fan module is a Hot Swappable CRU. The rear fan module is located at the rear of the chassis.
WHAT ACTIONS ARE REQUIRED:
CAUTION - If the fan module fails, replace it as soon as possible to maintain server availability.
A) Locate a Faulty Fan Module
View the following LED, which is lit when a fan module fault is detected:
- Fan Module (FM4) Fault LED on the rear of the server.
When the amber Service Required LED is lit, a fault has occurred on that fan module.
B) Removing the Rear Fan Module
1. Grasp the handle of the fan module and move the lever to the right
2. Pull the fan module out from the chassis by the lever.
C) Install a Fan Module
1. Align the fan module to the location where it installs into the chassis.
2. Slide the fan module into the chassis until the lever clicks, securing the fan module in place.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify Service Processor Functionality
PARTS NOTE:
refer to: https://support.oracle.com/handbook_private/Systems/Netra_T4_2/components.html#Fan
REFERENCE INFORMATION:
Netra T4-2 Service Manual http://docs.oracle.com/cd/E21893_01/index.html
References
<NOTE:1483194.1> - Commands to run to fully clear ILOM/SP, faultmgmt shell, and FMA faults on the T3-x and T4-x Servers
Attachments
This solution has no attachment