Solution Type  Technical Instruction Sure

Solution  1592619.1 :   How to Replace a Sun Server X4-2L Left LED Indicator Module  


Related Items
  • Oracle SuperCluster T5-8 Full Rack
  •  
  • Exadata X4-2 Hardware
  •  
  • Sun Server X4-2L
  •  
  • Big Data Appliance X4-2 Hardware
  •  
  • Exadata X4-2 Full Rack
  •  
  • Big Data Appliance X4-2 Full Rack
  •  
  • Oracle SuperCluster T5-8 Half Rack
  •  
  • Exadata X4-2 Quarter Rack
  •  
  • Exadata X4-8 Hardware
  •  
  • Big Data Appliance X4-2 Starter Rack
  •  
  • Zero Data Loss Recovery Appliance X4 Hardware
  •  
  • Exadata X4-2 Half Rack
  •  
  • Exadata X3-8 Hardware
  •  
  • Big Data Appliance X4-2 In-Rack Expansion
  •  
  • Exadata X4-2 Eighth Rack
  •  
  • Oracle SuperCluster T5-8 Hardware
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
  • Exadata X3-8b Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Exadata X4-2 Full Rack - Version All Versions to All Versions [Release All Releases]
Exadata X4-2 Eighth Rack - Version All Versions to All Versions [Release All Releases]
Zero Data Loss Recovery Appliance X4 Hardware - Version All Versions and later
Big Data Appliance X4-2 Full Rack - Version All Versions and later
Big Data Appliance X4-2 Starter Rack - Version All Versions and later
x86_64

Goal

How to Replace a Sun Server X4-2L Left LED Indicator Module.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Server X4-2L Training

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Server X4-2L Left LED Indicator Module needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications and OS.  Then power off the server and remove the AC power cords from the system.

A data backup is not a prerequisite but is a wise precaution.

Note:

If this server is part of an Exadata, ZDLRA or SuperCluster, please follow shutdown instructions in DOC ID: 1188080.1

If this server is part of a Big Data Appliance X4-2, please follow shutdown instruction in DOC ID: 2099858.1

 

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Prepare the server for service.

  1. Power off the server and disconnect the power cords from the power supplies.
  2. Extend the server to the maintenance position in the rack.
  3. Remove Top Cover
  4. Attach an anti-static wrist strap.

2. Remove the left indicator module.

  1. Remove the two No. 2 Phillips screws that secure the LED indicator module to the server front panel
  2. Disconnect the LED indicator module cable from the motherboard, and gently pull the cable through the chassis mid-plane and side wall of the server chassis
  3. Remove the LED indicator module from the server front panel and place it on an antistatic mat.

3. Install the Replacement left indicator module.

  1. Push the LED indicator module cable through the side wall and mid-plane of the server chassis
  2. Reconnect the LED indicator module cable to the motherboard.
  3. Insert and tighten the two No. 2 Phillips screws to secure the LED indicator module to the server front panel.

4. Return the Server to operation

  1. Remove any anti-static measures that were used.
  2. Re-install the Top Cover
  3. Return the server to it's normal operating position within the rack.
  4. Re-install the AC power cords and any data cables that were removed.
  5. Power on server. Verify that the Power/OK indicator led lights steady on.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot up system and verify full functionality

Note:

If this server is part of an Exadata, ZDLRA or SuperCluster, please follow restart instructions in step 7 of DOC ID: 1188080.1

If this server is part of a Big Data Appliance X4-2, please follow restart instructions in DOC ID: 2099858.1

 

REFERENCE INFORMATION:
Sun Server X4-2L Documentation

http://docs.oracle.com/cd/E36974_01/index.html

Steps to shut down or reboot an Exadata storage cell without affecting ASM (Doc ID 1188080.1)

Steps to Gracefully Shutdown and Power on a Single Node on Oracle Big Data Appliance Prior to Maintenance (Doc ID 2099858.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback