Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1592317.1
Update Date:2018-05-16
Keywords:

Solution Type  Technical Instruction Sure

Solution  1592317.1 :   How to Replace a Sun Server X4-2 PCIe Card  


Related Items
  • Exalogic Elastic Cloud X4-2 Hardware
  •  
  • Exalogic Elastic Cloud X4-2 Full Rack
  •  
  • Zero Data Loss Recovery Appliance X4 Hardware
  •  
  • Exalogic Elastic Cloud X4-2 Quarter Rack
  •  
  • Sun Server X4-2
  •  
  • Exalogic Elastic Cloud X4-2 Eighth Rack
  •  
  • Exalogic Elastic Cloud X4-2 Half Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




Applies to:

Exalogic Elastic Cloud X4-2 Hardware - Version X4 and later
Zero Data Loss Recovery Appliance X4 Hardware - Version All Versions to All Versions [Release All Releases]
Exalogic Elastic Cloud X4-2 Eighth Rack - Version X4 and later
Exalogic Elastic Cloud X4-2 Quarter Rack - Version X4 and later
Exalogic Elastic Cloud X4-2 Half Rack - Version X4 and later
x86_64

Goal

How to Replace a Sun Server X4-2 PCIe Card.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Server X4-2 PCIe Card needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications and OS.  Then power off the server and remove the AC power cords from the system.

A data backup is not a prerequisite but is a wise precaution.

Animation videos are available to demonstrate the PCIe Card replacement process for these servers. please refer to the following links:

Sun Server X4-2 Service Animations - MP4 and HTML versions at http://docs.oracle.com/cd/E36975_01/html/E49470/index.html

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Prepare the server for service.

  1. Power off the server and disconnect the power cords from the power supplies.
  2. Extend the server to the maintenance position in the rack.
  3. Attach an anti-static wrist strap.
  4. Remove the top cover.

2. Locate and Remove the PCIe card.

  1. There are three external and one internal PCIe slots in the system. They are numbered 1, 2, and 3 from left to right when you view the server from the rear. (The internal PCIe slot 4 is reserved for an internal SAS controller, replacement of this card is detailed in Doc ID 1592272.1)
  2. Identify the PCIe card to be replaced and disconnect any external or internal cables from the card. Note the cable locations and their order to ensure they are reinstalled in their proper locations.
  3. For cards installed in either the slot 1 or 2 risers:
    1. lift the green-tabbed latch on the rear of the server's chassis next to the PCIe slot to release the PCIe card's rear bracket.
    2. Lift the riser release lever with one hand and use your other hand to remove the riser from the motherboard
    3. place the riser and card on an anti-static mat and make a note of the slot in which the PCIe riser was originally installed so that it can be reinstalled into it's proper slot.
  4. For cards installed in the Slot 3 and 4 PCIe riser:
    1. open the green-tabbed latch located on the rear of the server's chassis next to the PCIe slot 3 to release the PCIe card holding bracket.
    2. To release the riser from the motherboard connector, lift the riser's green-tabbed release lever to the open position.
    3. Slide the plastic PCIe card retainer, which is mounted on the side of the chassis, forward to release the card(s) installed in the riser
    4. Grasp the riser with both hands and remove it from the server
    5. Disconnect the SAS storage drive (HDD) cables from the internal HBA card installed in PCIe slot 4 Note the cable locations and their order to ensure they are reinstalled in their proper locations.
    6. place the riser and cards on an anti-static mat and make a note of the slot in which the PCIe riser was originally installed so that it can be reinstalled into it's proper slot.
  5. Remove the PCIe card from the PCIe riser. Hold the riser in one hand and use your other hand to carefully pull the PCIe card connector out of the riser.
  6. Disconnect the rear bracket that is attached to the PCIe card from the rear of the PCIe riser.
  7. Place the PCIe card on an antistatic mat.

3. Replace the PCIe card.

  1. Remove the replacment PCIe card from it's anti-static bag and place on an anti-static mat.
  2. Insert the rear bracket that is attached to the PCIe card into the PCIe riser.
  3. Hold the riser in one hand and use your other hand to carefully insert the PCIe card connector into the Riser.
  4. Install the PCIe riser with the installed PCIe card into the server.
  5. For cards installed in either the slot 1 or 2 risers:
    1. raise the PCIe riser release lever (marked with a green tab) to the open (up) position
    2. Making sure to replace the riser into the same position from which it was removed, gently press the riser into the motherboard connector until it seats and press the green-tabbed, riser release lever to the closed (down) position.
    3. Close the green-tabbed latch on the rear of the server's chassis next to the applicable PCIe slot to secure the PCIe card's rear bracket to the server's chassis.
  6. For the PCIe slots 3 and 4 riser,
    1. reconnect the SAS cable(s) to the internal HBA card.Be sure to connect the SAS cable for storage drives 0 through 3 (HDDs 0-3) to the connector that is farther from the riser in which the HBA card is installed.
    2. Raise the PCIe riser green-tabbed release lever to the open (up) position and gently press the riser into the motherboard connector until it seats.
    3. Ensure that the rear bracket on the internal HBA card in PCIe slot 4 is connected to the slot in the server's chassis side wall. If the bracket is not connected, remove the riser and reposition it so that the rear bracket connects to the side wall, then gently press the riser into the motherboard connector.
    4. Slide the plastic PCIe card retainer that is mounted on the side of the chassis toward the back of the server to secure the card(s) installed in the riser.
    5. Press the green-tabbed release lever on the PCIe riser to the closed (down) position.
    6. To secure the PCIe card's rear bracket to the server, close the green-tabbed latch on the rear of the server's chassis.
  7. Reconnect any external or internal cables that were previously disconnected to the replacement PCIe card.

4.Return the Server to operation

  1. Replace the top cover
  2. Remove any anti-static measures that were used.
  3. Return the server to it's normal operating position within the rack.
  4. Re-install the AC power cords and any data cables that were removed but not yet replaced.
  5. Login to the ILOM and check to see if any faults were logged against the PCIe slot. If so clear the fault by logging into the fault managment shell. -  
    > start /SP/faultmgmt/shell
    Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

    faultmgmtsp> fmadm faulty
    ...
    FRU : /SYS/MB/PCIE2
    ...
    faultmgmtsp> fmadm repaired /SYS/MB/PCIE2
    faultmgmtsp> fmadm faulty -a
    No faults found
    faultmgmtsp> exit
  6. Power on server. Verify that the Power/OK indicator led lights steady on.

 

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot up system and verify full functionality

REFERENCE INFORMATION:
Sun Server X4-2 Documentation

http://docs.oracle.com/cd/E36975_01/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.