Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1591926.1
Update Date:2018-04-28
Keywords:

Solution Type  Technical Instruction Sure

Solution  1591926.1 :   How to Configure the Session Director to Use the Rear Console Port  


Related Items
  • Net-Net 3810
  •  
  • Acme Packet 4500
  •  
  • Net-Net 4250
  •  
  • Acme Packet 3820
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Session Delivery Network>SN-SND: Acme Service Provider
  •  




In this Document
Goal
Solution


Applies to:

Acme Packet 4500 - Version S-Cx6.0.x and later
Net-Net 3810 - Version S-Cx6.0.x and later
Acme Packet 3820 - Version S-Cx6.0.x and later
Net-Net 4250 - Version S-C4.1.4 and later
Acme Packet OS

Goal

 How to configure the Session Director (SD) to use the rear console port.

Solution

There are 2 methods to configure the Session Director (SD) to use the rear console port: first (A) is shorter and usually more convenient but not applicable in all cases and second (B) is a bit longer but applicable in all cases.

- Method (A):
==========
The SD to be configured must first meet the following before any attempt to configure rear console access.

1. SD-II only
2. Boot-loader must be Jan 2005 or higher.
3. Software load 2.00 or higher.
4. Front console port access configured and in working condition.

To determine the information you can use the following commands:

ACME-SD# show version boot


Bootloader Info
---------------
Bootloader Date: 01/21/2005 08:17:07
Mainboard: SD-II
Processor: xxxxx
Serial Number: xxxxxxxxxxxx
Mainboard Rev: 1.32

ACME-SD# show version
ACME Firmware 2.0.0 P2
06/01/05

Once you determine that the SD meets the requirements, the following steps can be done. This process requires the SD to be rebooted. On an high availability (HA) system, please run the procedure first on the standby and fail it over when the system reboots and all sync flags have become true.

Procedure to change console port to rear access:

1. From a front console connection reboot SD.
2. Stop the auto-boot process by hitting the space bar when prompted.
3. At the acme packet boot prompt: type in P
4. Enter Y to change the port being used.
5. The change requires a reboot.
6. At the prompt type in @ to reboot the SD.

Once the SD starts to reboot, communication will be lost. Connect the SD's front console port to the rear console (console 2). Depending on how fast the cable is moved, there may be messages on the bootup. Hit enter to get a password prompt if the SD has completed the boot process.

To return to using the front console port, just follow the same process as above. Simultaneous console access to both is not possible.

Here is an example of the change:

Acme Packet Net-Net Session Director II
Creation date: Jan 21 2005, 08:17:26

Initializing system memory........ done.

Press the space bar to stop auto-boot...
1
[Acme Packet Boot]: P
Enter Y to change the console port or anything else to abort: Y

The rear port will be used for the console when the system is rebooted
[Acme Packet Boot]: @

boot device : wancom
unit number : 0
processor number : 0
file name : /tffs0/sd200p2.gz
inet on ethernet (e) : 2.2.2.2:ffff0000
host inet (h) :
gateway inet (g) : 1.1.1.1
user (u) : vxftp
ftp password (pw) : vxftp
flags (f) : 0x100008

Attaching to TFFS... done.
Decompressing image... 3882952 bytes uncompressed.
0x00265100 + 0x000f9750 + (0x00037040) + 0x00000148
Starting at 0x10000...

------ End of method (A) --------


- Method (B):
==========
This method takes a bit more time, however it works in all cases.

Before starting this method, be sure to have:

- A working console access to active console port.
- A diags sw version appropriated for the SD
(usually included under /tffs0 directory of the SD)

(Tested with diags_118.gz for SD-I and diags_124.gz for SD-II)

Procedure is as follows:

1. From console connection, change bootparams file name to boot using diags version and reboot.
2. Log in to diags mode (password=flatspin) and enter diags Menu (dm)  NOTE: 4500/3800 would use 'dc' to access diags.
3. Choose "Diagnostic Utilities Menu" (10)
4. Choose "Set Console Port" ( (18) in diags_124.gz, (17) in diags_118.gz )
5. Then choose either (1) to set Front console or (2) to set Rear console
6. Confirm typing "Y"
7. Go back one menu (4)
8. Choose "Set Boot Parameters"( (21) or (20) depending of diags version)
9. Set boot image file name back to the sw version.
10. Exit from all Diag Menus and then type "reboot" in vxWorks prompt.

Once SD starts to boot, the console port change takes effect, so move
the cable to the other console port to continue access to SD via console.

An Example of the console port change including whole printouts is in the attached file.