![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1591433.1 : Sun Storage 7000 Unified Storage System: Offlining a disk before replacement is NOT supported
In this Document
Applies to:Sun Storage 7410 Unified Storage System - Version All Versions and laterSun ZFS Storage 7120 - Version All Versions and later Sun ZFS Storage 7320 - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later Sun Storage 7110 Unified Storage System - Version All Versions and later 7000 Appliance OS (Fishworks) GoalZFS Storage Appliance: Offlining a (failed) disk before replacement is NOT SUPPORTED
SolutionThe ZFSSA BUI/CLI offers the ability to offline a drive. Faulted devices are already avoided, so this option should only be required if a disk is exhibiting performance problems that do not result in pathological failure. It is not possible to offline a disk that would prevent access to data (i.e. offlining both halves of a mirror). Maintenance--Hardware--Select DiskShelves/Show details and offline the disk using "Offline disk" option
From CLI CLI> maintenance hardware select <chassisID> select disk select <Disk number> set offline=true
Offlining the disk manually from BUI/CLI prior replacement before replacement is NOT SUPPORTED. If you take a drive offline, replace the drive, and try to bring it online, it remains in the faulted state. If the original faulted disk is sent back after replacement please engage Storage-TSC for assistance. In case the disk was offlined by TSC/FE prior replacement for any reasons and replaced with a new one and new disk is not detected,
Check for relevancy - 10-May-2018
References<BUG:15566832> - SUNBT6847353 REQUEST ABILITY TO OFFLINE A DRIVE AND ACTIVATE A SPAREAttachments This solution has no attachment |
||||||||||||||||
|