Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1588506.1
Update Date:2016-09-05
Keywords:

Solution Type  Technical Instruction Sure

Solution  1588506.1 :   How to Remove and Replace a Netra X4200 M2 Power Supply  


Related Items
  • Sun Netra X4200 M2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Netra X4200 M2 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 How to Remove and Replace a Netra X4200 M2 Power Supply

Solution

 DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER/ADMINISTRATOR NEED:
Basic Sun hardware skills, familiarity or training for X4200 platform.

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The server’s redundant hot-pluggable power supplies enable you to remove and replace a power supply without shutting the server down provided that the other power supply is online and working

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Identify which power supply requires replacement.
A lighted amber LED on a power supply indicates that a failure was detected. You can also use the show faults command at the sc> prompt
2. Disconnect the power cord from the faulty power supply.
3. Grasp the power supply handle and push the power supply latch to the right.
4. Pull the power supply out of the chassis.
5. Installation is the reverse of this procedure.
6. Clean the error message by using the section C - Post-Repair Procedures from the document: PSH Procedural Article for ILOM-Based Diagnosis <Document: 1155200.1>

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:
Sun Netra X4200 M2 http://docs.oracle.com/cd/E19203-01/index.html