![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1587435.1 : SL150 - How To Change The Assignment of the Bridge Drive.
How to select another drive as the Bridged drive. In this Document
Created from <SR 3-7857759661> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SL150 2.0 Bridge Drive GoalThe bridge drive is the drive assigned to a whole library or a partition through which all SCSI control of the library/partition and drives passes. A failure of the Bridge drive will result in library failure. On occasion, or if setting up new partitions, it is desirable to change which drive is the bridge drive. Changing the bridged drive is only possible in 2.00 (1.32) and above firmware versions.
SolutionThe Bridge drive can be changed using the SL150 GUI by undertaking the following steps. N.B. The library/partition will need to go offline to perform this change but will go back online, if desired, once the change has been accomplished. Please ensure backup applications are taken offline before the change is attempted. 1. Log into the SL150 GUI 2. On the left-hand side select 'Configuration' 3. The current configuration is displayed. 4. Select , at upper left, the 'Configure' icon. The Configuration Wizard starts. 5. Select the 'Configure Library Settings' option. 6. Select 'Library Bridged Drive' - Select the chosen drive - Click Next - The changed drive will be identified in blue under 'Library Settings' - Select 'Accept all changes' box - Select Apply - Select 'ok' 6. Wait for 'Completed' to be displayed alongside 'Actions' and the status bar to reach 100% completion and the configuration change completion notification. This should take a few minutes. 7. Confirm the change under the 'Configuration' tab. 8. Bring backup applications back online. Attachments This solution has no attachment |
||||||||||||||
|