Asset ID: |
1-71-1587425.1 |
Update Date: | 2015-02-04 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1587425.1
:
How to Replace a Sun Blade X4-2B Memory DIMM
Related Items |
- Sun Blade 6000 System
- Sun Blade X4-2B Server Module
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade X4-2B Server Module - Version All Versions and later
Information in this document applies to any platform.
Goal
How to replace a Memory DIMM in a Sun Blade X4-2B Server Module.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific skills required.
TASK COMPLEXITY: 0
DELIVERY REQUIREMENT:
Maintenance window may be required
Time Estimate: 30 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
- Data backup not required but recommended as a precaution.
- Orderly shutdown of applications, then the OS and power down of server.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Prepare for servicing:
a. Power off the server module.
b. Remove the server module from the chassis and lay it flat, cover side up, on an anti-static mat.
Caution - After removing the server from the chassis insert a filler panel into an empty slot to reduce the possibility of a system shutdown.
c. Attach an anti-static wrist strap.
d. Remove the top cover.
2. To remove faulty DIMM,
a. Identify the location of the faulty DIMM. To identify a faulty DIMM, press and hold the blue Fault Remind button on the motherboard (SW3001). (LED is off: DIMM is operating properly, LED is on (amber): DIMM is faulty and should be replaced.)
b. Rotate both DIMM slot ejectors outward.
Caution – If you are not immediately inserting a replacement DIMM into the empty DIMM socket, you should insert a DIMM filler panel in the socket.
3. To install a DIMM:
a. Determine the DIMM socket location to populate.
Note – If the DIMM socket contains a filler panel, you will need to remove the DIMM filler panel prior to installing a DIMM into the DIMM socket.
b. Ensure that the ejector lever at each end of the memory socket are fully open (rotated outward) to accept the new DIMM.
c. Align the DIMM notch to the DIMM connector key.
d. Using both thumbs, press the DIMM straight down into the DIMM connector slot until both ejector levers close.
e. Install the cover on the server.
f. Reinsert the server module in the chassis slot.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
REFERENCE INFORMATION:
Sun Blade X4-2B Server Module Service Manual
http://docs.oracle.com/cd/E37035_01/index.html
Attachments
This solution has no attachment