Solution Type Technical Instruction Sure Solution 1587420.1 : How to Replace a Sun Blade X4-2B REM (RAID Expansion Module)
In this Document
Applies to:Sun Blade X4-2B Server Module - Version All Versions and laterSun Blade 6000 System - Version Not Applicable and later Information in this document applies to any platform. GoalHow to remove and replace a RAID Expansion Module (REM) in a Sun Blade X4-2B Server Module. SolutionDISPATCH INSTRUCTIONS TASK COMPLEXITY: 0 DELIVERY REQUIREMENT: Caution - After removing the server from the chassis insert a filler panel into an empty slot to reduce the possibility of a system shutdown. Close the REM latch downwards. Locate the REM support bracket on the motherboard, and slide the REM card at an angle under the flanges into the support bracket, then press the module carefully into the connector. To install the REM card, gently push down on the connector end of the card until the card is fully seated under the REM card retaining spring. An audible click occurs when the spring secures the card.
Remove the existing REM card by pulling the REM card out at an angle away from the support bracket. Transfer the REM card cache battery from the old REM to the new replacement REM. Close the REM latch downwards. Slide the new REM card at an angle under the flanges into the support bracket, then press it carefully into the connector. To install the REM card, gently push down on the connector end of the card until the card is fully seated under the REM card retaining spring. An audible click occurs when the spring secures the card. Install the cover on the server. OBTAIN CUSTOMER ACCEPTANCE Attachments This solution has no attachment |
||||||||||||||
|