Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1583425.1
Update Date:2013-11-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  1583425.1 :   VSM - How to modify the VSM to display RTD and CLink names in the SMF type 255 report  


Related Items
  • Sun StorageTek VSM5 System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Goal
Solution
References


Created from <SR 3-7690532631>

Applies to:

Sun StorageTek VSM5 System - Version All Versions and later
Information in this document applies to any platform.

Goal

How to configure the Virtual Storage Manager (VSM) to display Cluster Links (CLinks) and Real Tape Drive (RTD) names in the System Management Facility (SMF) reports?

Solution

If the customer requires names to be displayed in SMF records, then the following can be modified in the VSM.

 

1. In the VSM Detached Operator's Panel (DOP) click on Configuration.

2. Click on Channel Status and the Channel Status Panel will be displayed.

3. Under the name column, click on the section associated with the card and port or link.

4. In the name field, enter the desired name and click Continue to display a subscreen with the

    message success indicateing the configuration change completed successfully

5. Save the session and go back to the Channel Status Panel and modify the next port

6. Once finished, have the customer run the report and verify the names are displayed.



References

<NOTE:1577820.1> - How to obtain the Real Tape Drive (RTD) identification (ID) information from the Virtual Storage Manager (VSM)
<NOTE:1487938.1> - VSM - Performance Problem Analysis
<NOTE:1014342.1> - What Are The SMF Record Subtypes Generated By VTCS?

Attachments
This solution has no attachment