Solution Type  Technical Instruction Sure

Solution  1582643.1 :   How to enable new QLogic 9200 switch blades within Enterprise Fabric Manager  


Related Items
  • Qlogic SANbox 9200 Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Qlogic switch
  •  


Steps to be follow in order to for newly installed  Qlogic  blade made active

In this Document
Goal
Solution


Created from <SR 3-7767711346>

Applies to:

Qlogic SANbox 9200 Switch - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

After installing a new blade or plate in a QLogic SANbox 9200 switch, its display in Enterprise Fabric Manager may be grayed out.

This article presents the method to cause the new blade or plate to display as active.


Solution

Connect one of the ports on the new blade to a Fibre channel node/device such that the FC link is up/active.

For example, move an existing connection from an existing blade port to a port on the new blade. Enterprise Fabric Manager will then display the new blade correctly.