Solution Type Technical Instruction Sure Solution 1579228.1 : SL8500 - How to Set The Library Network Configuration to a Known Value
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterInformation in this document applies to any platform. Applicable to 8.30 code and greater. GoalHow to Set The Library Network Configuration to a Known Value. The command will allow the field to set the library network configuration to a known value; 10.10.0.1. An example when it might be used is to reconfigure the library IP addresses so one does not need to delete gateways, old routes, etc. Note: In an RE (Redundant Electronics) configuration it does not reset the inactive interface and the user must log into each side to reset the perspective interface SolutionIn RE configuration each side will need to be cleared while logged into that side. The command does not work if you use config side x, you have to be logged into the card you are clearing. =~=~=~=~=~=~=~=~=~=~=~= PuTTY log 2013.07.25 18:48:55 =~=~=~=~=~=~=~=~=~=~=~= Attachments This solution has no attachment |
||||||||||||||
|