Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1578904.1
Update Date:2018-05-22
Keywords:

Solution Type  Technical Instruction Sure

Solution  1578904.1 :   How to Replace a Sun Server X3-2L (Sun Fire X4270 M3) SAS Expander Assembly  


Related Items
  • Exadata X3-2 Hardware
  •  
  • SPARC SuperCluster T4-4 Full Rack
  •  
  • Oracle SuperCluster T5-8 Full Rack
  •  
  • Big Data Appliance X3-2 Hardware
  •  
  • Big Data Appliance X3-2 Full Rack
  •  
  • Big Data Appliance X3-2 In-Rack Expansion
  •  
  • Exadata X3-2 Half Rack
  •  
  • Oracle SuperCluster T5-8 Half Rack
  •  
  • Exadata X3-2 Full Rack
  •  
  • Exadata X3-8 Hardware
  •  
  • SPARC SuperCluster T4-4 Half Rack
  •  
  • Exadata X3-2 Eighth Rack
  •  
  • Oracle SuperCluster T5-8 Hardware
  •  
  • SPARC SuperCluster T4-4
  •  
  • Exadata X3-2 Quarter Rack
  •  
  • Sun Server X3-2L
  •  
  • Big Data Appliance X3-2 Starter Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




Oracle Confidential PARTNER - Available to partners (SUN).
Reason: internal CAP

Applies to:

Exadata X3-2 Hardware - Version All Versions and later
Exadata X3-2 Full Rack - Version All Versions and later
Exadata X3-8 Hardware - Version All Versions and later
Oracle SuperCluster T5-8 Hardware - Version All Versions and later
SPARC SuperCluster T4-4 Half Rack - Version All Versions and later
x86_64

Goal

How to Replace a Sun Server X3-2L (Sun Fire X4270 M3) SAS Expander Assembly.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Server X3-2L (Sun Fire X4270 M3) Training

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Server X3-2L (Sun Fire X4270 M3) SAS Expander Assembly needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

If the system is still up and functioning, the administrator should perform an orderly and graceful shutdown of applications and OS.  Then power off the server and remove the AC power cords from the system.

A data backup is not a prerequisite but is a wise precaution.

Note:

If this server is part of an Exadata or SuperCluster, please follow shutdown instructions in DOC ID: 1188080.1

If this server is part of a Big Data Appliance X3-2, please follow shutdown instruction in DOC ID: 2099858.1

 

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Prepare the server for service.

  1. Power off the server and disconnect the power cords from the power supplies.
  2. Extend the server to the maintenance position in the rack.
  3. Attach an anti-static wrist strap.
  4. Remove the top cover.

2. Remove the SAS expander.

  1. Disconnect SAS/SATA cables from the SAS expander module making note of their locations so that they may be re-connected in the same positions.
  2. To disconnect the HBA cable and the SAS/SATA cables from the SAS expander module, press the latch, and then pull out to disengage each cable from the SAS expander module.
  3. To disconnect the SAS/SATA cables from the front storage drive backplane and the SAS expander module, press the latch, and then pull out to disengage the cables from each storage drive backplane.
  4. If they are installed disconnect the rear storage drive SAS cables from the SAS expander module, press the latch, and then pull up to disengage the disk drive SAS drive cable from the SAS expander module.
  5. Remove the SAS expander module from the chassis:
    1. Locate and loosen the four black push pins that secure the SAS expander module to the server's chassis. Loosen each push pin by pulling up on the pin until it clicks into the open position
    2. Grasp the sides of the SAS expander module, and gently lift the module to disengage the module from the chassis connector
  6. Place the SAS expander module aside on an antistatic mat.

3. Replace the SAS expander.

  1. Remove the replacement SAS Expander from it's anti-static bag and place on an anti-static mat.
  2. Install the SAS expander module.
    1. Lower the SAS expander module into the server chassis, and gently push down on the module to engage the chassis connector.
    2. Push down on the four black push pins to secure the SAS expander module to the server's chassis.
  3. Connect the HBA cable and SAS cables to the SAS expander module
  4. Route the SAS cables from the disk backplane between the fan modules and between processors and DIMMs in the cable trough.
  5. If present Install the cable connectors into the rear-mounted storage drive backplane.To reconnect the rear-mounted storage drive SAS cables to the SAS expander module, plug each cable into its top SAS expander module connector until you hear an audible click.
  6. Making sure to reconnect the cables in the same order as they were previously installed reconnect the SAS/SATA cables to the SAS expander module. To reconnect the HBA cable and the SAS/SATA cables to the SAS expander module, plug each cable into its SAS expander module connector until you hear an audible click.
  7. To reconnect the front storage drive SAS/SATA cables to the SAS expander module, plug each cable into its SAS expander module connector until you hear and audible click
  8. Place the cables into cable tie-downs, and secure them with the tie-downs

4. Return the Server to operation

  1. Replace the top cover
  2. Remove any anti-static measures that were used.
  3. Return the server to it's normal operating position within the rack.
  4. Re-install the AC power cords and any data cables that were removed.
  5. Power on server. Verify that the Power/OK indicator led lights steady on.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot up system and verify full functionality

Note:

If this server is part of an Exadata or SuperCluster, please follow restart instructions in step 7 of DOC ID: 1188080.1

If this server is part of a Big Data Appliance X3-2, please follow restart instructions in DOC ID: 2099858.1

 

REFERENCE INFORMATION:
Sun Server X3-2L Documentation

http://docs.oracle.com/cd/E23393_01/index.html

Steps to shut down or reboot an Exadata storage cell without affecting ASM (Doc ID 1188080.1)