![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1572388.1 : T10000D - Cooling the Tape Drive
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek T10000D Tape Drive - Version All Versions and laterInformation in this document applies to any platform. GoalCooling the Tape Drive. SolutionThe T10000D tape drive does NOT have internal cooling fans within the drive brick. To provide drive cooling, it is critical for the drive to either be installed in an SL8500 or SL3000 drive tray or be connected to the cooling tool. The Tool, PN 7052542 will be available to order in September 2013. Note: T10000C and T10000D do NOT use the same drive tray. Note: The SL3000 Fan Assembly FRU is PN 7052546. The SL300 Fan Assembly is for one fan only, so, 2 fans are required per tray and each comes with a fan and a bracket. The SL8500 Fan Assembly FRU is PN 7052400. This assembly comes with 2 fans and a bracket. Attachments This solution has no attachment |
||||||||||||||
|