![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1572073.1 : IBM/HP LTO5/6 - Preferred Speed Setting for Fibre Channel
In this Document
Applies to:HP LTO6 Tape Drive - Version All Versions and laterIBM LTO6 Tape Drive - Version All Versions and later HP LTO5 Tape Drive - Version All Versions and later IBM LTO5 Tape Drive - Version All Versions and later Information in this document applies to any platform. GoalWhat is the preferred setting for Fibre Channel on the drive? 8GB or auto negotiate? SolutionIt depends on the Fibre Channel switch or the HBA that the drive is connected to. If connecting the 8 Gb drives to a 2 Gb or 4 Gb Fibre Channel switch or HBA, it is recommended forcing the ports on the FC switch or HBA to 2 or 4 Gb. This information is valid for IBM and HP LTO 5 and 6 drives. If you experience connection issues with the LTO5/6 drives on a 16Gb or 8Gb FC switch, the ports on the switch should be forced to a negotiation speed of 8Gb.
Attachments This solution has no attachment |
||||||||||||||
|