![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1568668.1 : How to Diagnose and Troubleshoot a System Battery failure on SPARC T3/T4/T5 Systems
In this Document
Applies to:Netra SPARC T5-1B Server Module - Version All Versions and laterSPARC T5-2 - Version All Versions and later SPARC T5-4 - Version All Versions and later SPARC T5-8 - Version All Versions and later SPARC T3-1 - Version All Versions and later Information in this document applies to any platform. GoalThe following document provides instructions on recognizing and properly diagnosing a System Battery failure on SPARC T3/T4/T5 Systems SolutionThe voltage of the server's real-time-clock backup battery is dropping. This is a normal behaviour and requires that the 3V Lithium Coin Cell Battery,
Target | Property | Value --------------------+------------------------+--------------------------------- /SP/faultmgmt/0 | fru | /SYS/MB/BAT /SP/faultmgmt/0/ | class | fault.chassis.battery.fail faults/0 | | /SP/faultmgmt/0/ | sunw-msg-id | SPT-8000-G3 faults/0 | | /SP/faultmgmt/0/ | component | /SYS faults/0 | | /SP/faultmgmt/0/ | uuid | 6b9b859a-9ba1-c629-93af-8911dc87 faults/0 | | d382 /SP/faultmgmt/0/ | timestamp | 2013-07-09/22:28:39 faults/0 | | /SP/faultmgmt/0/ | detector | /SYS/MB/V_BAT faults/0 | | /SP/faultmgmt/0/ | product_serial_number | AB00012345 faults/0 | | /SP/faultmgmt/0/ | chassis_serial_number | AB00012345 faults/0 | |
b) In the Service Processor ILOM command line interface, in the fault management shell: faultmgmtsh> fmadm faulty ------------------- ------------------------------------ -------------- -------- Fault class : fault.chassis.battery.fail FRU : /SYS/MB/BAT Description : The real-time-clock backup battery is approaching the end of Response : The chassis-wide service required LED will be illuminated. Impact : ILOM and/or Host time of day may not be retained when power Action : The administrator should review the ILOM event log for
References<NOTE:1443798.1> - How to Remove and Replace a SPARC T3-1B System Battery:ATR:1443798.1:0<NOTE:1518044.1> - Collect ILOM snapshot on T3-x and T4-x systems without an active network management connection <NOTE:1020204.1> - Collecting snapshot on ILOM 3.x and later platforms <NOTE:1159646.1> - SPT-8000-G3 - Battery failure imminent <NOTE:1525974.1> - How to Replace a SPARC T5-2 Battery <NOTE:1530638.1> - How to Remove and Replace a SPARC T5-8 Server Battery:ATR:1530638.1:0 <NOTE:1527323.1> - How to Remove and Replace a SPARC T5-4 Server Battery:ATR:1527323.1:0 <NOTE:1530441.1> - How to Remove and Replace a SPARC T5-1B System Battery:ATR:1530441.1:0 <NOTE:1410273.1> - How to Replace a SPARC T4-1 or Netra T4-1 System Battery:ATR:1410273.1:0 <NOTE:1415497.1> - How to Replace a SPARC T4-2 or Netra T4-2 Battery:ATR:1415497.1:0 <NOTE:1416313.1> - How to Remove and Replace a SPARC T4-4 Server Battery:ATR:1416313.1:0 <NOTE:1461220.1> - How to Remove and Replace a SPARC T4-1B System Battery:ATR:1461220.1:0 <NOTE:1299326.1> - How to Replace a SPARC T3-1 or Netra T3-1 System Battery:ATR:2441:0 <NOTE:1335074.1> - How to Remove and Replace a SPARC T3-2 Battery:ATR:1335074.1:0 <NOTE:1333874.1> - How to Remove and Replace a SPARC T3-4 Server Battery:ATR:1333874.1:0 Attachments This solution has no attachment |
||||||||||||||||
|