Solution Type  Technical Instruction Sure

Solution  1568668.1 :   How to Diagnose and Troubleshoot a System Battery failure on SPARC T3/T4/T5 Systems  


Related Items
  • Netra SPARC T3-1B
  •  
  • SPARC T3-4
  •  
  • SPARC T3-1
  •  
  • SPARC T3-1B
  •  
  • Netra SPARC T5-1B Server Module
  •  
  • Netra SPARC T4-2 Server
  •  
  • SPARC T4-2
  •  
  • Netra SPARC T4-1 Server
  •  
  • SPARC T5-8
  •  
  • Netra SPARC T4-1B
  •  
  • SPARC T3-2
  •  
  • SPARC T4-1B
  •  
  • SPARC T4-1
  •  
  • SPARC T5-2
  •  
  • SPARC T5-4
  •  
  • SPARC T5-1B
  •  
  • SPARC T4-4
  •  
  • Netra T3-1
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T4
  •  




In this Document
Goal
Solution
References


Applies to:

Netra SPARC T5-1B Server Module - Version All Versions and later
SPARC T5-2 - Version All Versions and later
SPARC T5-4 - Version All Versions and later
SPARC T5-8 - Version All Versions and later
SPARC T3-1 - Version All Versions and later
Information in this document applies to any platform.

Goal

The following document provides instructions on recognizing and properly diagnosing a System Battery failure on SPARC T3/T4/T5 Systems

Solution

The voltage of the server's real-time-clock backup battery is dropping. This is a normal behaviour and requires that the 3V Lithium Coin Cell Battery,
which is located on the system board (or mainboard) of the server, gets replaced.

In addition to illuminating the service required LED, the server will show the following symptoms:

a) In the Service Processor ILOM command line interface:


-> show faulty

Target              | Property               | Value                           
--------------------+------------------------+---------------------------------
/SP/faultmgmt/0     | fru                    | /SYS/MB/BAT                     
/SP/faultmgmt/0/    | class                  | fault.chassis.battery.fail      
 faults/0           |                        |                                 
/SP/faultmgmt/0/    | sunw-msg-id            | SPT-8000-G3                     
 faults/0           |                        |                                 
/SP/faultmgmt/0/    | component              | /SYS                            
 faults/0           |                        |                                 
/SP/faultmgmt/0/    | uuid                   | 6b9b859a-9ba1-c629-93af-8911dc87
 faults/0           |                        | d382                            
/SP/faultmgmt/0/    | timestamp              | 2013-07-09/22:28:39             
 faults/0           |                        |                                 
/SP/faultmgmt/0/    | detector               | /SYS/MB/V_BAT                   
 faults/0           |                        |                                 
/SP/faultmgmt/0/    | product_serial_number  | AB00012345                      
 faults/0           |                        |                                 
/SP/faultmgmt/0/    | chassis_serial_number  | AB00012345                      
 faults/0           |                        |                        

 

b) In the Service Processor ILOM command line interface, in the fault management shell:

faultmgmtsh> fmadm faulty
 

------------------- ------------------------------------ -------------- --------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2013-07-09/22:28:39 6b9b859a-9ba1-c629-93af-8911dc87d382 SPT-8000-G3 Minor

Fault class : fault.chassis.battery.fail

FRU : /SYS/MB/BAT
(Part Number: unknown)
(Serial Number: unknown)

Description : The real-time-clock backup battery is approaching the end of
its lifetime.

Response : The chassis-wide service required LED will be illuminated.

Impact : ILOM and/or Host time of day may not be retained when power
is lost.

Action : The administrator should review the ILOM event log for
additional information pertaining to this diagnosis. Please
refer to the Details section of the Knowledge Article for
additional information.


Corrective Action

1. Collect either an ILOM snapshot (How To) or at least the output of the ILOM "->show faulty" command.

2. open a Service Request and provide the Service Engineer with the ILOM snapshot or ILOM output.
    The Service Engineer will request that the dispatch ships a replacement battery to you.

    Hint: Please keep in mind that this battery is a customer replaceable unit.

3. familiarize yourself with the battery replacement procedure. 
    The "References" section contains links to server specific replacement procedures.

References

<NOTE:1443798.1> - How to Remove and Replace a SPARC T3-1B System Battery:ATR:1443798.1:0
<NOTE:1518044.1> - Collect ILOM snapshot on T3-x and T4-x systems without an active network management connection
<NOTE:1020204.1> - Collecting snapshot on ILOM 3.x and later platforms
<NOTE:1159646.1> - SPT-8000-G3 - Battery failure imminent
<NOTE:1525974.1> - How to Replace a SPARC T5-2 Battery
<NOTE:1530638.1> - How to Remove and Replace a SPARC T5-8 Server Battery:ATR:1530638.1:0
<NOTE:1527323.1> - How to Remove and Replace a SPARC T5-4 Server Battery:ATR:1527323.1:0
<NOTE:1530441.1> - How to Remove and Replace a SPARC T5-1B System Battery:ATR:1530441.1:0
<NOTE:1410273.1> - How to Replace a SPARC T4-1 or Netra T4-1 System Battery:ATR:1410273.1:0
<NOTE:1415497.1> - How to Replace a SPARC T4-2 or Netra T4-2 Battery:ATR:1415497.1:0
<NOTE:1416313.1> - How to Remove and Replace a SPARC T4-4 Server Battery:ATR:1416313.1:0
<NOTE:1461220.1> - How to Remove and Replace a SPARC T4-1B System Battery:ATR:1461220.1:0
<NOTE:1299326.1> - How to Replace a SPARC T3-1 or Netra T3-1 System Battery:ATR:2441:0
<NOTE:1335074.1> - How to Remove and Replace a SPARC T3-2 Battery:ATR:1335074.1:0
<NOTE:1333874.1> - How to Remove and Replace a SPARC T3-4 Server Battery:ATR:1333874.1:0

Attachments
This solution has no attachment