Solution  1568284.1 :   Sun Storage Common Array Manager: How to Redistribute Volumes on a Sun Storage 6000/2500/Flexline Array  


Related Items
  • Sun Storage Flexline 280 Array
  •  
  • Sun Storage 2540-M2 Array
  •  
  • Sun Storage Common Array Manager (CAM)
  •  
  • Sun Storage 2540 Array
  •  
  • Sun Storage 2510 Array
  •  
  • Sun Storage 6780 Array
  •  
  • Sun Storage 6180 Array
  •  
  • Sun Storage 6130 Array
  •  
  • Sun Storage Flexline 380 Array
  •  
  • Sun Storage 2530 Array
  •  
  • Sun Storage Flexline 240 Array
  •  
  • Sun Storage 6580 Array
  •  
  • Sun Storage 6140 Array
  •  
  • Sun Storage 6540 Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Disk Software>SN-DK: CAM
  •  




Applies to:

Sun Storage 2540-M2 Array - Version Not Applicable and later
Sun Storage Flexline 240 Array - Version Not Applicable and later
Sun Storage Flexline 280 Array - Version Not Applicable and later
Sun Storage Flexline 380 Array - Version Not Applicable and later
Sun Storage Common Array Manager (CAM) - Version 6.0 and later
Information in this document applies to any platform.

Goal

This document describes how to redistribute ownership of all volumes on an Sun Storage 6000/2500/Flexline array back to their preferred controller via the Sun Storage Common Array Manager (CAM) software.
This is often done in response to an xx.66.1010 alarm: "The following volume(s) is/are not managed by their preferred controller."

Solution

Caution: Using the "Redistribute Volumes" function may cause a change of ownership of some volume(s) to the other controller.
Modifying this array setting can impact volume access or redundancy on the attached hosts, depending on the configuration, host-type and multipathing drivers set-up, because volume failover(s) will occur.

In the CAM GUI :

  1. Click Sun Storage Common Array Manager.
    The navigation pane and the Storage System Summary page are displayed.
  2. In the navigation pane, choose the array on which you want to redistribute the volumes and select "Administration"
    The "Administration" page for that array is displayed.
  3. Click the "Redistribute Volumes" button near the top of the page
    The Redistribute Volumes confirmation dialog box is displayed.
  4. Review the information and then click "OK" - the Redistribution will start immediately.

 

In the CAM GUI via the Service Advisor :

  1. Select "Array Troubleshooting and Recovery"

  2. Select "Redistribute Volumes"

  3. Follow the procedure on the right panel.

 

In the CAM CLI :

Location for sscs :

Solaris : /opt/SUNWstkcam/bin/
Linux : /opt/sun/cam/bin/
Windows : C:\Program Files\Sun\Common Array Manager\bin

The following command will Redistribute Volumes :

sscs service -a <array-name> redistribute

Example (Solaris) :

# ./sscs service -a st6180 redistribute
Executing the redistribute command on st6180
Started redistribute command job process:2013.07.11.11.10.31.545 on st6180
Completion Status: Success

 

 

Do you still have questions?  You can use My Oracle Support Communities.  Communities put you in touch with industry professionals like yourself.  They are monitored by Oracle support engineers, so you can expect reliable and correct answers.  Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.

 