Solution Type Technical Instruction Sure Solution 1568284.1 : Sun Storage Common Array Manager: How to Redistribute Volumes on a Sun Storage 6000/2500/Flexline Array
Applies to:Sun Storage 2540-M2 Array - Version Not Applicable and laterSun Storage Flexline 240 Array - Version Not Applicable and later Sun Storage Flexline 280 Array - Version Not Applicable and later Sun Storage Flexline 380 Array - Version Not Applicable and later Sun Storage Common Array Manager (CAM) - Version 6.0 and later Information in this document applies to any platform. GoalThis document describes how to redistribute ownership of all volumes on an Sun Storage 6000/2500/Flexline array back to their preferred controller via the Sun Storage Common Array Manager (CAM) software. SolutionCaution: Using the "Redistribute Volumes" function may cause a change of ownership of some volume(s) to the other controller.
Modifying this array setting can impact volume access or redundancy on the attached hosts, depending on the configuration, host-type and multipathing drivers set-up, because volume failover(s) will occur. In the CAM GUI :
In the CAM GUI via the Service Advisor :
In the CAM CLI :Location for sscs :
Solaris : /opt/SUNWstkcam/bin/ Linux : /opt/sun/cam/bin/ Windows : C:\Program Files\Sun\Common Array Manager\bin The following command will Redistribute Volumes : sscs service -a <array-name> redistribute
Example (Solaris) : # ./sscs service -a st6180 redistribute
Executing the redistribute command on st6180 Started redistribute command job process:2013.07.11.11.10.31.545 on st6180 Completion Status: Success
Do you still have questions? You can use My Oracle Support Communities. Communities put you in touch with industry professionals like yourself. They are monitored by Oracle support engineers, so you can expect reliable and correct answers. Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.