Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1567901.1
Update Date:2013-08-14
Keywords:

Solution Type  Technical Instruction Sure

Solution  1567901.1 :   Brocade FC switch - Sfp Supply Voltage XX, is below low boundary(High=3600, Low=3150)  


Related Items
  • Brocade 24000 Director
  •  
  • Brocade 48000 Director
  •  
  • Brocade 12000 Fabric Switch
  •  
  • Brocade DCX Backbone
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
  •  




In this Document
Goal
Solution
References


Created from <SR 3-7307112031>

Applies to:

Brocade 48000 Director - Version Not Applicable to Not Applicable [Release N/A]
Brocade DCX Backbone - Version Not Applicable to Not Applicable [Release N/A]
Brocade 24000 Director - Version All Versions to Not Applicable [Release All Releases to N/A]
Brocade 12000 Fabric Switch - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

On a Brocade switch we can see these warnings on errdump output:

What do they mean?

Is there any faulty hardware?

2013/03/30-19:43:35, [FW-1050], 2926,, WARNING, swicth1, Sfp Supply Voltage 25, is below low boundary(High=3600, Low=3150). Current value is 3148 mV.
2013/03/30-20:23:35, [FW-1050], 3042,, WARNING, swicth1, Sfp Supply Voltage 16, is below low boundary(High=3600, Low=3150). Current value is 3143 mV.
2013/03/30-20:23:35, [FW-1050], 3043,, WARNING, swicth1, Sfp Supply Voltage 25, is below low boundary(High=3600, Low=3150). Current value is 3141 mV.
2013/03/30-21:18:31, [FW-1050], 3061,, WARNING, swicth1, Sfp Supply Voltage 16, is below low boundary(High=3600, Low=3150). Current value is 3149 mV.
2013/03/30-21:18:31, [FW-1050], 3062,, WARNING, swicth1, Sfp Supply Voltage 25, is below low boundary(High=3600, Low=3150). Current value is 3148 mV.
2013/05/25-12:15:18, [FW-1050], 3170,, WARNING, swicth1, Sfp Supply Voltage 25, is below low boundary(High=3600, Low=3150). Current value is 3149 mV.
2013/05/25-14:35:19, [FW-1050], 3171,, WARNING, swicth1, Sfp Supply Voltage 16, is below low boundary(High=3600, Low=3150). Current value is 3149 mV.

 

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk/Tape Storage Area Networks

Solution

As explained on Brocade community "SFP voltage below Low Threshold"
http://community.brocade.com/thread/6412

You have to check the data sheet of your SFP if the reported values are within the technical specs or not.
FabricWatch reports some defaults which may not fit to this specific SFP.

 

On our case, from switchshow command we can see the slot and port number for index 16 and 25 :

Index Slot Port Address Media Speed State Proto
===================================================
16 2 0 011000 id N2 Online F-Port 50:05:07:60:1f:40:4e:29

25 2 9 011900 id N2 Online F-Port 50:05:07:60:1f:40:4c:78

 

From "sfpshow all" command we can see on these ports we have Long Wave SFP FINISAR "FTRJ-1319-7D-2.5" :

=============
Slot 2/Port 0:
=============
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 0501001200000000 100,200_MB/s SM lw Long_dist
Encoding: 1 8B10B
Baud Rate: 21 (units 100 megabaud)
Length 9u: 10 (units km)
Length 9u: 100 (units 100 meters)
Length 50u: 0 (units 10 meters)
Length 62.5u:0 (units 10 meters)
Length Cu: 0 (units 1 meter)
Vendor Name: FINISAR CORP.
Vendor OUI: 00:90:65
Vendor PN: FTRJ-1319-7D-2.5
Vendor Rev:
Wavelength: 1310 (units nm)
Options: 0012 Loss_of_Sig,Tx_Disable
BR Max: 0
BR Min: 0
Serial No: P68068M
Date Code: 040816
Temperature: 36 Centigrade
Current: 27.192 mAmps
Voltage: 3151.4 mVolts
RX Power: 715.8 uWatts
TX Power: 182.2 uWatts



=============
Slot 2/Port 9:
=============
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 0501001200000000 100,200_MB/s SM lw Long_dist
Encoding: 1 8B10B
Baud Rate: 21 (units 100 megabaud)
Length 9u: 10 (units km)
Length 9u: 100 (units 100 meters)
Length 50u: 0 (units 10 meters)
Length 62.5u:0 (units 10 meters)
Length Cu: 0 (units 1 meter)
Vendor Name: FINISAR CORP.
Vendor OUI: 00:90:65
Vendor PN: FTRJ-1319-7D-2.5
Vendor Rev:
Wavelength: 1310 (units nm)
Options: 0012 Loss_of_Sig,Tx_Disable
BR Max: 0
BR Min: 0
Serial No: P680684
Date Code: 040816
Temperature: 39 Centigrade
Current: 28.416 mAmps
Voltage: 3152.0 mVolts
RX Power: 733.6 uWatts
TX Power: 241.0 uWatts

 

That SFP is equivalent to the "FTLF1319F1xTL" model
Based on Finisar web page, on the Product Specification for SFP FTLF1319F1xTL the Supply Voltage range goes from 3.00 to 3.60 volts , and Current values reported by fabric watch are around 3.14 volts, that means we should not worry about it.

 

References

<NOTE:1016436.1> - SAN Brocade FC switch - Encode Out Errors in porterrshow - How to identify bad SFP or FC Cable or FC device

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback